Chaffoteaux Error Code Error 101 / 103 / 104: Meaning, Multimeter Diagnosis & Fix

Fault code Error 101 / 103 / 104 on Chaffoteaux units (Pigma Green, Urbia Green, Mira Advance, Inoa, Talia, Alixia (Grupo Ariston)) indicates: Overtemperature in the primary circuit (101) or insufficient circulation / excessive thermal gradient (103 / 104). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Chaffoteaux Error 101 / 103 / 104)

Manufacturer / BrandChaffoteaux
Error CodeError 101 / 103 / 104
System / CategoryBoilers & Heating
Compatible ModelsPigma Green, Urbia Green, Mira Advance, Inoa, Talia, Alixia (Grupo Ariston)
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsNTC Chaffoteaux probes at 25°C: 10 kΩ

2. Guided Symptom Troubleshooting Matrix

🔎 Does error 101 or 104 appear a few seconds after turning on the heating, making a bubbling noise?
✓ Scenario A: Yes (Confirmed)

The water does not circulate through the exchanger because the **circulator pump is blocked**, the **return filter (located on the right under the metal clip)** is clogged with black sludge from the radiators or there is air in the circuit.

✕ Scenario B: No (Not Present)

Close the flow/return valves, remove and clean the lower mesh filter, unlock the pump shaft and activate the purge cycle by holding down the **Brush/Purge** button.

3. Step-by-Step Multimeter Testing Procedure (Error 101 / 103 / 104)

  1. Safety Power Isolation: Disconnect the Chaffoteaux unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Error 101 / 103 / 104 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: NTC Chaffoteaux probes at 25°C: 10 kΩ.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Chaffoteaux Error Error 101 / 103 / 104

🔄 Chaffoteaux Error 101 / 103 / 104 Reset: Clean the return hydraulic filter, unlock the circulator pump rotor and press 'Reset'.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for Chaffoteaux NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for Chaffoteaux Error 101 / 103 / 104?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Chaffoteaux Error Code Error 101 / 103 / 104

What does Chaffoteaux error code Error 101 / 103 / 104 mean?

Chaffoteaux Error 101 / 103 / 104: Overtemperature in the primary circuit (101) or insufficient circulation / excessive thermal gradient (103 / 104) (Pigma Green, Urbia Green, Mira Advance, Inoa, Talia, Alixia (Grupo Ariston)). Multimeter Specs: NTC Chaffoteaux probes at 25°C: 10 kΩ.

How do I reset Chaffoteaux fault code Error 101 / 103 / 104?

Clean the return hydraulic filter, unlock the circulator pump rotor and press 'Reset'.

What multimeter values should I check for Chaffoteaux code Error 101 / 103 / 104?

NTC Chaffoteaux probes at 25°C: 10 kΩ