Chaffoteaux Error Code Error 101 / 103 / 104: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Chaffoteaux Error 101 / 103 / 104)
| Manufacturer / Brand | Chaffoteaux |
|---|---|
| Error Code | Error 101 / 103 / 104 |
| System / Category | Boilers & Heating |
| Compatible Models | Pigma Green, Urbia Green, Mira Advance, Inoa, Talia, Alixia (Grupo Ariston) |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | NTC Chaffoteaux probes at 25°C: 10 kΩ |
2. Guided Symptom Troubleshooting Matrix
The water does not circulate through the exchanger because the **circulator pump is blocked**, the **return filter (located on the right under the metal clip)** is clogged with black sludge from the radiators or there is air in the circuit.
Close the flow/return valves, remove and clean the lower mesh filter, unlock the pump shaft and activate the purge cycle by holding down the **Brush/Purge** button.
3. Step-by-Step Multimeter Testing Procedure (Error 101 / 103 / 104)
- Safety Power Isolation: Disconnect the Chaffoteaux unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault Error 101 / 103 / 104 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: NTC Chaffoteaux probes at 25°C: 10 kΩ.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Chaffoteaux Error Error 101 / 103 / 104
Check OEM & aftermarket availability for Chaffoteaux NTC Temperature Sensor:
⚡ Open in Interactive Simulator →
5. Frequently Asked Questions: Chaffoteaux Error Code Error 101 / 103 / 104
What does Chaffoteaux error code Error 101 / 103 / 104 mean?
Chaffoteaux Error 101 / 103 / 104: Overtemperature in the primary circuit (101) or insufficient circulation / excessive thermal gradient (103 / 104) (Pigma Green, Urbia Green, Mira Advance, Inoa, Talia, Alixia (Grupo Ariston)). Multimeter Specs: NTC Chaffoteaux probes at 25°C: 10 kΩ.
How do I reset Chaffoteaux fault code Error 101 / 103 / 104?
Clean the return hydraulic filter, unlock the circulator pump rotor and press 'Reset'.
What multimeter values should I check for Chaffoteaux code Error 101 / 103 / 104?
NTC Chaffoteaux probes at 25°C: 10 kΩ