Chaffoteaux Error Code 108: Meaning, Multimeter Diagnosis & Fix

Fault code 108 on Chaffoteaux units (Pigma Green, Urbia Green, Mira Advance, Inoa, Talia) indicates: Required filling: Lack of water pressure (< 0.6 bar). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Chaffoteaux 108)

Manufacturer / BrandChaffoteaux
Error Code108
System / CategoryBoilers & Heating
Compatible ModelsPigma Green, Urbia Green, Mira Advance, Inoa, Talia
Severity LevelLow Severity · Maintenance Advisory
Multimeter SpecsNominal pressure: 1.2 - 1.5 bar

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does the message '108 Installation filling' appear on the display?
βœ“ Scenario A: Yes (Confirmed)

Locate the two lower filler cocks (blue and grey/black), open them simultaneously up to 1.4 bar and close both.

βœ• Scenario B: No (Not Present)

Dirty hydraulic pressure switch or pressure sensor.

3. Step-by-Step Multimeter Testing Procedure (108)

  1. Safety Power Isolation: Disconnect the Chaffoteaux unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault 108 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Nominal pressure: 1.2 - 1.5 bar.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Chaffoteaux Error 108

πŸ”„ Chaffoteaux 108 Reset: It disappears automatically when exceeding 1.0 bar.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Chaffoteaux Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Chaffoteaux 108?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Chaffoteaux Error Code 108

What does Chaffoteaux error code 108 mean?

Chaffoteaux 108: Required filling: Lack of water pressure (< 0.6 bar) (Pigma Green, Urbia Green, Mira Advance, Inoa, Talia). Multimeter Specs: Nominal pressure: 1.2 - 1.5 bar.

How do I reset Chaffoteaux fault code 108?

It disappears automatically when exceeding 1.0 bar.

What multimeter values should I check for Chaffoteaux code 108?

Nominal pressure: 1.2 - 1.5 bar