Engineering Review: 2026-11-21 · SAE J2012 / IEC / OEM Verified
ESENDEFRIT
Boilers & Heating High Severity · Safety Lockout

Chaffoteaux Error Code 101: Meaning, Multimeter Diagnosis & Fix

Fault code 101 on Chaffoteaux units (Pigma Green, Urbia Green, Mira Advance, Inoa, Talia) indicates: Primary circuit overtemperature. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Chaffoteaux 101)

Manufacturer / BrandChaffoteaux
Error Code101
System / CategoryBoilers & Heating
Compatible ModelsPigma Green, Urbia Green, Mira Advance, Inoa, Talia
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsNTC Chaffoteaux probes at 25°C: 10 kΩ

2. Guided Symptom Troubleshooting Matrix

🔎 Does it show 101 as soon as you turn on the burner?
✓ Scenario A: Yes (Confirmed)

Lack of circulation: the return filter (bottom right) is clogged with mud or the pump is blocked.

✕ Scenario B: No (Not Present)

Bleed the air from the primary exchanger.

3. Step-by-Step Multimeter Testing Procedure (101)

  1. Safety Power Isolation: Disconnect the Chaffoteaux unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault 101 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: NTC Chaffoteaux probes at 25°C: 10 kΩ.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Chaffoteaux Error 101

🔄 Chaffoteaux 101 Reset: Clean the filter, let it cool and press 'Reset'.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for Chaffoteaux NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for Chaffoteaux 101?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Chaffoteaux Error Code 101

What does Chaffoteaux error code 101 mean?

Chaffoteaux 101: Primary circuit overtemperature (Pigma Green, Urbia Green, Mira Advance, Inoa, Talia). Multimeter Specs: NTC Chaffoteaux probes at 25°C: 10 kΩ.

How do I reset Chaffoteaux fault code 101?

Clean the filter, let it cool and press 'Reset'.

What multimeter values should I check for Chaffoteaux code 101?

NTC Chaffoteaux probes at 25°C: 10 kΩ