Chaffoteaux Error Code 101: Meaning, Multimeter Diagnosis & Fix
Fault code 101 on Chaffoteaux units (Pigma Green, Urbia Green, Mira Advance, Inoa, Talia) indicates: Primary circuit overtemperature. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.
1. Technical Specifications & Multimeter Values (Chaffoteaux 101)
| Manufacturer / Brand | Chaffoteaux |
|---|---|
| Error Code | 101 |
| System / Category | Boilers & Heating |
| Compatible Models | Pigma Green, Urbia Green, Mira Advance, Inoa, Talia |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | NTC Chaffoteaux probes at 25°C: 10 kΩ |
2. Guided Symptom Troubleshooting Matrix
🔎 Does it show 101 as soon as you turn on the burner?
✓ Scenario A: Yes (Confirmed)
Lack of circulation: the return filter (bottom right) is clogged with mud or the pump is blocked.
✕ Scenario B: No (Not Present)
Bleed the air from the primary exchanger.
3. Step-by-Step Multimeter Testing Procedure (101)
- Safety Power Isolation: Disconnect the Chaffoteaux unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault 101 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: NTC Chaffoteaux probes at 25°C: 10 kΩ.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Chaffoteaux Error 101
🔄 Chaffoteaux 101 Reset: Clean the filter, let it cool and press 'Reset'.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?
Check OEM & aftermarket availability for Chaffoteaux NTC Temperature Sensor:
Want to use the interactive diagnostic wizard or electrical calculators for Chaffoteaux 101?
⚡ Open in Interactive Simulator →
⚡ Open in Interactive Simulator →
5. Frequently Asked Questions: Chaffoteaux Error Code 101
What does Chaffoteaux error code 101 mean?
Chaffoteaux 101: Primary circuit overtemperature (Pigma Green, Urbia Green, Mira Advance, Inoa, Talia). Multimeter Specs: NTC Chaffoteaux probes at 25°C: 10 kΩ.
How do I reset Chaffoteaux fault code 101?
Clean the filter, let it cool and press 'Reset'.
What multimeter values should I check for Chaffoteaux code 101?
NTC Chaffoteaux probes at 25°C: 10 kΩ