Error Code Technical Meaning Multimeter Specs
Baxi E01Lockout due to lack of ignition or no flame detectionStrict L/N polarity required | Ionization: > 1.2 µA
Baxi E02Safety thermostat activation due to overtemperatureSafety thermostat: 0 Ω closed (opens at > 98°C)
Baxi E03Smoke evacuation failure (Air pressure switch / Smoke thermostat)AC fan coil: 45-90 Ω | Pressure switch contact: 0 Ω when sucking
Baxi E05Heating flow NTC probe open or shortedNTC Baxi resistance at 25°C: 10 kΩ | At 40°C: 5.3 kΩ
Baxi E06Defective Domestic Hot Water (DHW) NTC probeNTC ACS resistance at 25°C: 10 kΩ
Baxi E10Hydraulic pressure switch open (Lack of water pressure)Pressure switch contact: Closed (0 Ω) with pressure > 0.6 bar
Baxi E110Overheat safety thermostat or flue gas thermostat tripped (Platform Platinum / Duo-Tec)safety limit thermostat: 0 Ω closed (< 95°C)
Baxi E118pressure hidráulica of the primary circuit demasiado baja (< 0.5 bar)pressure nominal of trabajo: 1.2 - 1.5 bar
Baxi E133Gas supply interruption / Ignition failure (Platinum Range)Condensate siphon cleared | Inlet gas pressure: 18-25 mbar
Baxi E25Subida of temperature demasiado rápida (> 1°C/seg): Pump blocked / jammed or falta of circulación (E25 / E26)Gradiente Maximum admisible: < 1.5°C due to segundo
Baxi E35Parasitic flame (Improper flame signal detection)Voltage between Neutral and Ground must be < 2V AC