Baxi Error Code E05: Meaning, Multimeter Diagnosis & Fix

Fault code E05 on Baxi units (Neodens Plus, Platinum Compact, Victoria Condens, Laura) indicates: Heating flow NTC probe open or shorted. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Baxi E05)

Manufacturer / BrandBaxi
Error CodeE05
System / CategoryBoilers & Heating
Compatible ModelsNeodens Plus, Platinum Compact, Victoria Condens, Laura
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsNTC Baxi resistance at 25°C: 10 kΩ | At 40°C: 5.3 kΩ

2. Guided Symptom Troubleshooting Matrix

🔎 Does error E05 appear as soon as you turn on the boiler without even starting it?
✓ Scenario A: Yes (Confirmed)

The feed NTC probe wire is loose, sulfated, or the probe is broken internally.

✕ Scenario B: No (Not Present)

The probe resistance goes out of range when heated; Replaces the NTC probe.

3. Step-by-Step Multimeter Testing Procedure (E05)

  1. Safety Power Isolation: Disconnect the Baxi unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault E05 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: NTC Baxi resistance at 25°C: 10 kΩ | At 40°C: 5.3 kΩ.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Baxi Error E05

🔄 Baxi E05 Reset: It is automatically cleared when a valid 10 kΩ NTC probe is connected.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for Baxi NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for Baxi E05?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Baxi Error Code E05

What does Baxi error code E05 mean?

Baxi E05: Heating flow NTC probe open or shorted (Neodens Plus, Platinum Compact, Victoria Condens, Laura). Multimeter Specs: NTC Baxi resistance at 25°C: 10 kΩ | At 40°C: 5.3 kΩ.

How do I reset Baxi fault code E05?

It is automatically cleared when a valid 10 kΩ NTC probe is connected.

What multimeter values should I check for Baxi code E05?

NTC Baxi resistance at 25°C: 10 kΩ | At 40°C: 5.3 kΩ