Ariston Β· 7 Verified Diagnostic Sheets
ESENDEFRIT
Boilers & Heating

Ariston Error Codes: Complete List (7 Faults), Causes & Reset

Complete technical directory of all 7 Ariston error codes (Boilers & Heating) with exact meanings, multimeter reference specs, and reset instructions.

Error Code Technical Meaning Multimeter Specs
Ariston 101Overtemperature in the primary circuit (> 102°C)NTC flow/return probes at 25°C: 10 kΞ©
Ariston 104Insufficient circulation flow (Excessive thermal gradient)Maximum allowable rise: < 20°C/second
Ariston 108Lack of water or insufficient pressure in the primary circuitRecommended pressure: 1.2 to 1.5 bar
Ariston 305Internal error of the electronic board (PCB)Mains voltage: 230V AC
Ariston 501No flame (Ignition failure)Ionization current: > 1.5 µA
Ariston E12Heating error in the first tank or open resistance (Flashing of all lights in Velis)Output tank resistance (1500W): ~35 Ξ© | Ariston NTC probe at 25°C: 10 kΞ©
Ariston E14Abnormal heating rate / Heating under vacuum or excess limeMagnesium anode and lime-free tank interior