Ariston Error Code 108: Meaning, Multimeter Diagnosis & Fix
Fault code 108 on Ariston units (Genus One, Clas One, Cares Premium, Alteas, Pigma) indicates: Lack of water or insufficient pressure in the primary circuit. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.
1. Technical Specifications & Multimeter Values (Ariston 108)
| Manufacturer / Brand | Ariston |
|---|---|
| Error Code | 108 |
| System / Category | Boilers & Heating |
| Compatible Models | Genus One, Clas One, Cares Premium, Alteas, Pigma |
| Severity Level | Low Severity · Maintenance Advisory |
| Multimeter Specs | Recommended pressure: 1.2 to 1.5 bar |
2. Guided Symptom Troubleshooting Matrix
π Is the pressure on the screen less than 0.6 bar?
β Scenario A: Yes (Confirmed)
Opens the two lower filler taps (on many Ariston/Chaffoteaux models there are two taps in series) up to 1.4 bar.
β Scenario B: No (Not Present)
Minimum pressure switch or pressure sensor clogged.
3. Step-by-Step Multimeter Testing Procedure (108)
- Safety Power Isolation: Disconnect the Ariston unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault 108 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Recommended pressure: 1.2 to 1.5 bar.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Ariston Error 108
π Ariston 108 Reset: It disappears automatically when exceeding 1.0 bar.
π οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?
Check OEM & aftermarket availability for Ariston Replacement Sensor / Part:
Want to use the interactive diagnostic wizard or electrical calculators for Ariston 108?
β‘ Open in Interactive Simulator β
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Ariston Error Code 108
What does Ariston error code 108 mean?
Ariston 108: Lack of water or insufficient pressure in the primary circuit (Genus One, Clas One, Cares Premium, Alteas, Pigma). Multimeter Specs: Recommended pressure: 1.2 to 1.5 bar.
How do I reset Ariston fault code 108?
It disappears automatically when exceeding 1.0 bar.
What multimeter values should I check for Ariston code 108?
Recommended pressure: 1.2 to 1.5 bar