Ariston Termos Β· 2 Verified Diagnostic Sheets
ESENDEFRIT
Boilers & Heating

Ariston Termos Error Codes: Complete List (2 Faults), Causes & Reset

Complete technical directory of all 2 Ariston Termos error codes (Boilers & Heating) with exact meanings, multimeter reference specs, and reset instructions.

Error Code Technical Meaning Multimeter Specs
Ariston Termos E10 / E11 / E20 / E21 (Calentamiento in Seco or NTC thermistor probe Velis)The Ariston Velis Evo / Pro1 Eco flat thermos flashes all lights or displays 'E10', 'E11', 'E20' or 'E21' and leaves the water coldAriston Velis dual NTC probe (white 4-wire connector): 10 kΞ© at 25°C on each pair of wires | Sheathed resistance 1500W: ~35 Ξ©
Ariston Termos E12 / E14 / Error Board / Plate or Ánodo Electrónico (Lydos Hybrid)The code 'E12', 'E14' or 'F3 / F4' appears on Ariston Velis thermos or Ariston Lydos Hybrid aerothermal hybridThermoses with ProTech electronic anode require that the water have a minimum conductivity (> 100 µS/cm) to close the circuit through the water
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Ariston Termos Replacement Sensor / Part: