Ariston Termos Error Code E10 / E11 / E20 / E21 (Calentamiento in Seco or NTC thermistor probe Velis): Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Ariston Termos E10 / E11 / E20 / E21 (Calentamiento in Seco or NTC thermistor probe Velis))
| Manufacturer / Brand | Ariston Termos |
|---|---|
| Error Code | E10 / E11 / E20 / E21 (Calentamiento in Seco or NTC thermistor probe Velis) |
| System / Category | Boilers & Heating |
| Compatible Models | Termos Electric Inteligentes Ariston (Velis Evo, Velis Tech, Velis WiFi, Lydos Hybrid, Lydos Eco, Pro1 Eco - Doble Tanque) |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | Ariston Velis dual NTC probe (white 4-wire connector): 10 kΩ at 25°C on each pair of wires | Sheathed resistance 1500W: ~35 Ω |
2. Guided Symptom Troubleshooting Matrix
In double tank water heaters **Ariston Velis (`E1X` = Main outlet tank / `E2X` = Inlet tank)**: • **E11 or E21 (Vacuum heating / Excess lime)**: The resistance is covered with a crust of lime so thick that the heat does not pass to the water and rises to 100°C in 10 seconds. First **turn off the thermos light for 5 minutes** to erase the electronic lock; If it jumps again 2 minutes after turning it on, you have to remove the lower flanges to clean the limescale and change the magnesium anode. • **E10 or E20 (NTC probe cut)**: With the thermos unplugged, remove the lower plastic cover and pull down the **2 black plastic rods (double NTC probes that are inserted dry inside a small metal tube)**. Measure its 4 thin wires: if one is open, put the original Ariston Velis NTC probe replacement (~€13 on Amazon, it can be changed in 2 minutes without emptying a single drop of water).
Unplug the thermos for 5 minutes; If it persists, remove the two lower NTC probe rods without emptying the water and check their resistance (~10 kΩ at 25°C).
3. Step-by-Step Multimeter Testing Procedure (E10 / E11 / E20 / E21 (Calentamiento in Seco or NTC thermistor probe Velis))
- Safety Power Isolation: Disconnect the Ariston Termos unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault E10 / E11 / E20 / E21 (Calentamiento in Seco or NTC thermistor probe Velis) for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Ariston Velis dual NTC probe (white 4-wire connector): 10 kΩ at 25°C on each pair of wires | Sheathed resistance 1500W: ~35 Ω.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Ariston Termos Error E10 / E11 / E20 / E21 (Calentamiento in Seco or NTC thermistor probe Velis)
Check OEM & aftermarket availability for Ariston Termos NTC Temperature Sensor:
⚡ Open in Interactive Simulator →
5. Frequently Asked Questions: Ariston Termos Error Code E10 / E11 / E20 / E21 (Calentamiento in Seco or NTC thermistor probe Velis)
What does Ariston Termos error code E10 / E11 / E20 / E21 (Calentamiento in Seco or NTC thermistor probe Velis) mean?
Ariston Termos E10 / E11 / E20 / E21 (Calentamiento in Seco or NTC thermistor probe Velis): The Ariston Velis Evo / Pro1 Eco flat thermos flashes all lights or displays 'E10', 'E11', 'E20' or 'E21' and leaves the water cold (Termos Electric Inteligentes Ariston (Velis Evo, Velis Tech, Velis WiFi, Lydos Hybrid, Lydos Eco, Pro1 Eco - Doble Tanque)). Multimeter Specs: Ariston Velis dual NTC probe (white 4-wire connector): 10 kΩ at 25°C on each pair of wires | Sheathed resistance 1500W: ~35 Ω.
How do I reset Ariston Termos fault code E10 / E11 / E20 / E21 (Calentamiento in Seco or NTC thermistor probe Velis)?
Cut power for 5 minutes; replace the plug-in NTC probe of the affected tank (E10 = outlet, E20 = inlet) or descale the sheathed resistance.
What multimeter values should I check for Ariston Termos code E10 / E11 / E20 / E21 (Calentamiento in Seco or NTC thermistor probe Velis)?
Ariston Velis dual NTC probe (white 4-wire connector): 10 kΩ at 25°C on each pair of wires | Sheathed resistance 1500W: ~35 Ω