Viessmann Vitocal Error Code 10 / 18: Meaning, Multimeter Diagnosis & Fix

Fault code 10 / 18 on Viessmann Vitocal units (Vitocal 200-S, 222-S, 200-A, 150-A, 250-A (Control Vitotronic 200)) indicates: short circuit (10) or open circuit (18) in la Probe / Sensor of temperature exterior. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Heat Pumps (Aerothermal) subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Viessmann Vitocal 10 / 18)

Manufacturer / BrandViessmann Vitocal
Error Code10 / 18
System / CategoryHeat Pumps (Aerothermal)
Compatible ModelsVitocal 200-S, 222-S, 200-A, 150-A, 250-A (Control Vitotronic 200)
Severity LevelLow Severity · Maintenance Advisory
Multimeter SpecsNTC thermistor probe exterior Viessmann (10 kΩ a 25°C | ~27.2 kΩ a 0°C)

2. Guided Symptom Troubleshooting Matrix

🔎 Does Viessmann Vitocal error code 10 / 18 return immediately after a full power cycle even when main supply voltage is stable?
✓ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (short circuit (10) or open circuit (18) in la Probe / Sensor of temperature exterior). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: NTC thermistor probe exterior Viessmann (10 kΩ a 25°C | ~27.2 kΩ a 0°C). If it reads open circuit (OL) or dead short, replace the faulty part.

✕ Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: Se restablece automáticamente in cuanto la lectura of resistance vuelve a rango.

3. Step-by-Step Multimeter Testing Procedure (10 / 18)

  1. Safety Power Isolation: Disconnect the Viessmann Vitocal unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault 10 / 18 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: NTC thermistor probe exterior Viessmann (10 kΩ a 25°C | ~27.2 kΩ a 0°C).
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Viessmann Vitocal Error 10 / 18

🔄 Viessmann Vitocal 10 / 18 Reset: Se restablece automáticamente in cuanto la lectura of resistance vuelve a rango.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for Viessmann Vitocal NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for Viessmann Vitocal 10 / 18?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Viessmann Vitocal Error Code 10 / 18

What does Viessmann Vitocal error code 10 / 18 mean?

Viessmann Vitocal 10 / 18: short circuit (10) or open circuit (18) in la Probe / Sensor of temperature exterior (Vitocal 200-S, 222-S, 200-A, 150-A, 250-A (Control Vitotronic 200)). Multimeter Specs: NTC thermistor probe exterior Viessmann (10 kΩ a 25°C | ~27.2 kΩ a 0°C).

How do I reset Viessmann Vitocal fault code 10 / 18?

Se restablece automáticamente in cuanto la lectura of resistance vuelve a rango.

What multimeter values should I check for Viessmann Vitocal code 10 / 18?

NTC thermistor probe exterior Viessmann (10 kΩ a 25°C | ~27.2 kΩ a 0°C)