Engineering Review: 2026-11-21 · SAE J2012 / IEC / OEM Verified
ESENDEFRIT
Heat Pumps (Aerothermal) Low Severity · Maintenance Advisory

NIBE Error Code Alarma 1 / 101 (BT1): Meaning, Multimeter Diagnosis & Fix

Fault code Alarma 1 / 101 (BT1) on NIBE units (Bombas of Calor Aerotermia and Geotermia F2040, F2120, S2125, VVM 310/320/500, SMO) indicates: Fault / Failure in la Probe / Sensor of temperature exterior BT1 (open circuit or short circuit). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Heat Pumps (Aerothermal) subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (NIBE Alarma 1 / 101 (BT1))

Manufacturer / BrandNIBE
Error CodeAlarma 1 / 101 (BT1)
System / CategoryHeat Pumps (Aerothermal)
Compatible ModelsBombas of Calor Aerotermia and Geotermia F2040, F2120, S2125, VVM 310/320/500, SMO
Severity LevelLow Severity · Maintenance Advisory
Multimeter SpecsNTC thermistor probe NIBE (BT1/BT2/BT6) a 25°C: 10 kΩ (o 15 kΩ in series F antiguas)

2. Guided Symptom Troubleshooting Matrix

🔎 Does NIBE error code Alarma 1 / 101 (BT1) return immediately after a full power cycle even when main supply voltage is stable?
✓ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (Fault / Failure in la Probe / Sensor of temperature exterior BT1 (open circuit or short circuit)). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: NTC thermistor probe NIBE (BT1/BT2/BT6) a 25°C: 10 kΩ (o 15 kΩ in series F antiguas). If it reads open circuit (OL) or dead short, replace the faulty part.

✕ Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: Se borra sola al reconectar la Probe / Sensor BT1 or reset alarma.

3. Step-by-Step Multimeter Testing Procedure (Alarma 1 / 101 (BT1))

  1. Safety Power Isolation: Disconnect the NIBE unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Alarma 1 / 101 (BT1) for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: NTC thermistor probe NIBE (BT1/BT2/BT6) a 25°C: 10 kΩ (o 15 kΩ in series F antiguas).
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear NIBE Error Alarma 1 / 101 (BT1)

🔄 NIBE Alarma 1 / 101 (BT1) Reset: Se borra sola al reconectar la Probe / Sensor BT1 or reset alarma.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for NIBE NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for NIBE Alarma 1 / 101 (BT1)?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: NIBE Error Code Alarma 1 / 101 (BT1)

What does NIBE error code Alarma 1 / 101 (BT1) mean?

NIBE Alarma 1 / 101 (BT1): Fault / Failure in la Probe / Sensor of temperature exterior BT1 (open circuit or short circuit) (Bombas of Calor Aerotermia and Geotermia F2040, F2120, S2125, VVM 310/320/500, SMO). Multimeter Specs: NTC thermistor probe NIBE (BT1/BT2/BT6) a 25°C: 10 kΩ (o 15 kΩ in series F antiguas).

How do I reset NIBE fault code Alarma 1 / 101 (BT1)?

Se borra sola al reconectar la Probe / Sensor BT1 or reset alarma.

What multimeter values should I check for NIBE code Alarma 1 / 101 (BT1)?

NTC thermistor probe NIBE (BT1/BT2/BT6) a 25°C: 10 kΩ (o 15 kΩ in series F antiguas)