NIBE Error Code Alarma 50 / 220: Meaning, Multimeter Diagnosis & Fix

Fault code Alarma 50 / 220 on NIBE units (Bombas of Calor Aerotermia and Geotermia F2040, F2120, S2125, VVM 310/320/500, SMO) indicates: Alarma of Alta pressure (High Pressure Alarm): flow rate insuficiente of Water in el condensador. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Heat Pumps (Aerothermal) subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (NIBE Alarma 50 / 220)

Manufacturer / BrandNIBE
Error CodeAlarma 50 / 220
System / CategoryHeat Pumps (Aerothermal)
Compatible ModelsBombas of Calor Aerotermia and Geotermia F2040, F2120, S2125, VVM 310/320/500, SMO
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsDiferencial óptimo between impulsión (BT12) and retorno (BT3): 5K a 8K

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does NIBE error code Alarma 50 / 220 return immediately after a full power cycle even when main supply voltage is stable?
βœ“ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (Alarma of Alta pressure (High Pressure Alarm): flow rate insuficiente of Water in el condensador). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: Diferencial óptimo between impulsión (BT12) and retorno (BT3): 5K a 8K. If it reads open circuit (OL) or dead short, replace the faulty part.

βœ• Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: clean el Filter of malla hidráulico and seleccionar 'Restablecer alarma (Reset alarm)' in la display NIBE.

3. Step-by-Step Multimeter Testing Procedure (Alarma 50 / 220)

  1. Safety Power Isolation: Disconnect the NIBE unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Alarma 50 / 220 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Diferencial óptimo between impulsión (BT12) and retorno (BT3): 5K a 8K.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear NIBE Error Alarma 50 / 220

πŸ”„ NIBE Alarma 50 / 220 Reset: clean el Filter of malla hidráulico and seleccionar 'Restablecer alarma (Reset alarm)' in la display NIBE.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Motor Run Capacitor)?

Check OEM & aftermarket availability for NIBE Motor Run Capacitor:

Want to use the interactive diagnostic wizard or electrical calculators for NIBE Alarma 50 / 220?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: NIBE Error Code Alarma 50 / 220

What does NIBE error code Alarma 50 / 220 mean?

NIBE Alarma 50 / 220: Alarma of Alta pressure (High Pressure Alarm): flow rate insuficiente of Water in el condensador (Bombas of Calor Aerotermia and Geotermia F2040, F2120, S2125, VVM 310/320/500, SMO). Multimeter Specs: Diferencial óptimo between impulsión (BT12) and retorno (BT3): 5K a 8K.

How do I reset NIBE fault code Alarma 50 / 220?

clean el Filter of malla hidráulico and seleccionar 'Restablecer alarma (Reset alarm)' in la display NIBE.

What multimeter values should I check for NIBE code Alarma 50 / 220?

Diferencial óptimo between impulsión (BT12) and retorno (BT3): 5K a 8K