Vaillant aroTHERM Error Code F.732 / F.733 / S.98 (Bajo flow rate / overload Compressor): Meaning, Multimeter Diagnosis & Fix

Fault code F.732 / F.733 / S.98 (Bajo flow rate / overload Compressor) on Vaillant aroTHERM units (Aerotermia Vaillant aroTHERM (Plus R290, Split, Pure - uniTOWER, Module Hidráulico MEH 60/97 and Control sensoCOMFORT / multiMATIC)) indicates: En la display of the uniTOWER or mando sensoCOMFORT of Vaillant aroTHERM aparece 'F.732', 'F.733' or 'F.752' (Fault / Failure of circulación of Water). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Heat Pumps (Aerothermal) subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Vaillant aroTHERM F.732 / F.733 / S.98 (Bajo flow rate / overload Compressor))

Manufacturer / BrandVaillant aroTHERM
Error CodeF.732 / F.733 / S.98 (Bajo flow rate / overload Compressor)
System / CategoryHeat Pumps (Aerothermal)
Compatible ModelsAerotermia Vaillant aroTHERM (Plus R290, Split, Pure - uniTOWER, Module Hidráulico MEH 60/97 and Control sensoCOMFORT / multiMATIC)
Severity LevelHigh Severity · Safety Lockout
Multimeter Specspressure óptima Vaillant aroTHERM: 1.5 a 2.0 bar | flow rate Minimum in funcionamiento: > 11-15 L/min

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does Vaillant aroTHERM error code F.732 / F.733 / S.98 (Bajo flow rate / overload Compressor) return immediately after a full power cycle even when main supply voltage is stable?
βœ“ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (En la display of the uniTOWER or mando sensoCOMFORT of Vaillant aroTHERM aparece 'F.732', 'F.733' or 'F.752' (Fault / Failure of circulación of Water)). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: pressure óptima Vaillant aroTHERM: 1.5 a 2.0 bar | flow rate Minimum in funcionamiento: > 11-15 L/min. If it reads open circuit (OL) or dead short, replace the faulty part.

βœ• Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: clean el vaso e imán of the Filter desfangador of retorno, subir pressure a 1.8 bar and press el Button of Rearme (Reset).

3. Step-by-Step Multimeter Testing Procedure (F.732 / F.733 / S.98 (Bajo flow rate / overload Compressor))

  1. Safety Power Isolation: Disconnect the Vaillant aroTHERM unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault F.732 / F.733 / S.98 (Bajo flow rate / overload Compressor) for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: pressure óptima Vaillant aroTHERM: 1.5 a 2.0 bar | flow rate Minimum in funcionamiento: > 11-15 L/min.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Vaillant aroTHERM Error F.732 / F.733 / S.98 (Bajo flow rate / overload Compressor)

πŸ”„ Vaillant aroTHERM F.732 / F.733 / S.98 (Bajo flow rate / overload Compressor) Reset: clean el vaso e imán of the Filter desfangador of retorno, subir pressure a 1.8 bar and press el Button of Rearme (Reset).
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Vaillant aroTHERM Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Vaillant aroTHERM F.732 / F.733 / S.98 (Bajo flow rate / overload Compressor)?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Vaillant aroTHERM Error Code F.732 / F.733 / S.98 (Bajo flow rate / overload Compressor)

What does Vaillant aroTHERM error code F.732 / F.733 / S.98 (Bajo flow rate / overload Compressor) mean?

Vaillant aroTHERM F.732 / F.733 / S.98 (Bajo flow rate / overload Compressor): En la display of the uniTOWER or mando sensoCOMFORT of Vaillant aroTHERM aparece 'F.732', 'F.733' or 'F.752' (Fault / Failure of circulación of Water) (Aerotermia Vaillant aroTHERM (Plus R290, Split, Pure - uniTOWER, Module Hidráulico MEH 60/97 and Control sensoCOMFORT / multiMATIC)). Multimeter Specs: pressure óptima Vaillant aroTHERM: 1.5 a 2.0 bar | flow rate Minimum in funcionamiento: > 11-15 L/min.

How do I reset Vaillant aroTHERM fault code F.732 / F.733 / S.98 (Bajo flow rate / overload Compressor)?

clean el vaso e imán of the Filter desfangador of retorno, subir pressure a 1.8 bar and press el Button of Rearme (Reset).

What multimeter values should I check for Vaillant aroTHERM code F.732 / F.733 / S.98 (Bajo flow rate / overload Compressor)?

pressure óptima Vaillant aroTHERM: 1.5 a 2.0 bar | flow rate Minimum in funcionamiento: > 11-15 L/min