Rain Bird / Hunter (Riego) Error Code NO AC / without Current: Meaning, Multimeter Diagnosis & Fix

Fault code NO AC / without Current on Rain Bird / Hunter (Riego) units (Programadores of Riego Automatic Rain Bird (ESP-RZXe, ESP-Me, ESP-TM2) and Hunter (X-Core, Pro-C, Eco-Logic)) indicates: The screen shows 'NO AC' (only the screen works with the memory battery but does not open any solenoid valve). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Pools & Lawn Mowers subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Rain Bird / Hunter (Riego) NO AC / without Current)

Manufacturer / BrandRain Bird / Hunter (Riego)
Error CodeNO AC / without Current
System / CategoryPools & Lawn Mowers
Compatible ModelsProgramadores of Riego Automatic Rain Bird (ESP-RZXe, ESP-Me, ESP-TM2) and Hunter (X-Core, Pro-C, Eco-Logic)
Severity LevelLow Severity · Maintenance Advisory
Multimeter SpecsProgrammer strip input: 24V AC - 26V AC (50/60 Hz)

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Do you see the time on the irrigation programmer screen, but it says 'NO AC' and no water comes out in any sector?
βœ“ Scenario A: Yes (Confirmed)

The internal battery is only used to keep the time: **to open the garden solenoid valves you necessarily need 24V AC from the transformer plugged into 230V**. 1) Check if the garage differential has tripped or if the socket where the programmer is connected does not have light. 2) In models with an external transformer, measure with the multimeter AC (V~) on the two screws **'24 VAC'** of the power strip: they must reach **24V - 26V AC**.

βœ• Scenario B: No (Not Present)

If the plug has 230V but the transformer gives 0V AC, the internal thermal fuse of the 24V AC transformer has blown due to a power surge.

3. Step-by-Step Multimeter Testing Procedure (NO AC / without Current)

  1. Safety Power Isolation: Disconnect the Rain Bird / Hunter (Riego) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault NO AC / without Current for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Programmer strip input: 24V AC - 26V AC (50/60 Hz).
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Rain Bird / Hunter (Riego) Error NO AC / without Current

πŸ”„ Rain Bird / Hunter (Riego) NO AC / without Current Reset: Restore 230V AC at the garage outlet or replace the 24V AC (1 Amp) transformer.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Rain Bird Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Rain Bird / Hunter (Riego) NO AC / without Current?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Rain Bird / Hunter (Riego) Error Code NO AC / without Current

What does Rain Bird / Hunter (Riego) error code NO AC / without Current mean?

Rain Bird / Hunter (Riego) NO AC / without Current: The screen shows 'NO AC' (only the screen works with the memory battery but does not open any solenoid valve) (Programadores of Riego Automatic Rain Bird (ESP-RZXe, ESP-Me, ESP-TM2) and Hunter (X-Core, Pro-C, Eco-Logic)). Multimeter Specs: Programmer strip input: 24V AC - 26V AC (50/60 Hz).

How do I reset Rain Bird / Hunter (Riego) fault code NO AC / without Current?

Restore 230V AC at the garage outlet or replace the 24V AC (1 Amp) transformer.

What multimeter values should I check for Rain Bird / Hunter (Riego) code NO AC / without Current?

Programmer strip input: 24V AC - 26V AC (50/60 Hz)