Engineering Review: 2026-11-21 Β· SAE J2012 / IEC / OEM Verified
ESENDEFRIT
Pools & Lawn Mowers Medium Severity · Protection Mode

Husqvarna Automower Error Code Atrapado / Levantado: Meaning, Multimeter Diagnosis & Fix

Fault code Atrapado / Levantado on Husqvarna Automower units (Automower 105, 305, 310, 315, 420, 430X, 450X, Gardena Sileno) indicates: 'Lifted' or 'Stuck' error in the middle of flat grass with no obstacles. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Pools & Lawn Mowers subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Husqvarna Automower Atrapado / Levantado)

Manufacturer / BrandHusqvarna Automower
Error CodeAtrapado / Levantado
System / CategoryPools & Lawn Mowers
Compatible ModelsAutomower 105, 305, 310, 315, 420, 430X, 450X, Gardena Sileno
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsCentered magnetic Hall collision and lift sensors

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does the robot say it has been lifted when it is on completely flat ground?
βœ“ Scenario A: Yes (Confirmed)

Underneath the top case, on the front posts that hold the lid, there is a **small cylindrical magnet** that reads the lift Hall sensor. It has filled with dry mud preventing the casing from lowering into place, or the magnet has fallen out of its holder.

βœ• Scenario B: No (Not Present)

Remove the top cover by pulling up, clean the mud from the rubber buffers and check the lift sensor magnet.

3. Step-by-Step Multimeter Testing Procedure (Atrapado / Levantado)

  1. Safety Power Isolation: Disconnect the Husqvarna Automower unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Atrapado / Levantado for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Centered magnetic Hall collision and lift sensors.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Husqvarna Automower Error Atrapado / Levantado

πŸ”„ Husqvarna Automower Atrapado / Levantado Reset: Clean the suspension columns of the casing and enter the PIN code + Start.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Husqvarna Automower Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Husqvarna Automower Atrapado / Levantado?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Husqvarna Automower Error Code Atrapado / Levantado

What does Husqvarna Automower error code Atrapado / Levantado mean?

Husqvarna Automower Atrapado / Levantado: 'Lifted' or 'Stuck' error in the middle of flat grass with no obstacles (Automower 105, 305, 310, 315, 420, 430X, 450X, Gardena Sileno). Multimeter Specs: Centered magnetic Hall collision and lift sensors.

How do I reset Husqvarna Automower fault code Atrapado / Levantado?

Clean the suspension columns of the casing and enter the PIN code + Start.

What multimeter values should I check for Husqvarna Automower code Atrapado / Levantado?

Centered magnetic Hall collision and lift sensors