Rain Bird / Hunter (Riego) Error Code ERR / MV / Zona in short circuit: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Rain Bird / Hunter (Riego) ERR / MV / Zona in short circuit)
| Manufacturer / Brand | Rain Bird / Hunter (Riego) |
|---|---|
| Error Code | ERR / MV / Zona in short circuit |
| System / Category | Pools & Lawn Mowers |
| Compatible Models | Programadores of Riego Automatic Rain Bird (ESP-RZXe, ESP-Me, ESP-TM2) and Hunter (X-Core, Pro-C, Eco-Logic) |
| Severity Level | Medium Severity · Protection Mode |
| Multimeter Specs | Irrigation solenoid coil resistance 24V AC (Rain Bird / Hunter): 24 Ω to 55 Ω | Programmer output voltage: 24V - 28V AC |
2. Guided Symptom Troubleshooting Matrix
It means that **there is an electrical short circuit (< 20 Ohms) in the solenoid coil of that solenoid valve in the manhole or in the buried cable**, and the programmer cuts it so as not to burn itself: 1) If it says **'MV ERR'**: the short is in the Master Valve or in the Well Pump Start Relay. 2) If it says **'3 ERR'**: the short is in solenoid valve No. 3. **Test with a multimeter in 1 minute**: Release the Common cable (C) and the cable of that zone (e.g. 3) in the programmer and measure Ohms between them; a healthy 24V AC solenoid should measure **between 20 Ω and 60 Ω**. If it measures less than 10 Ω, the valve solenoid is connected by water.
Unscrew the solenoid of the solenoid valve of that box and change it (€12) joining the cables with watertight connectors filled with silicone grease.
3. Step-by-Step Multimeter Testing Procedure (ERR / MV / Zona in short circuit)
- Safety Power Isolation: Disconnect the Rain Bird / Hunter (Riego) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault ERR / MV / Zona in short circuit for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Irrigation solenoid coil resistance 24V AC (Rain Bird / Hunter): 24 Ω to 55 Ω | Programmer output voltage: 24V - 28V AC.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Rain Bird / Hunter (Riego) Error ERR / MV / Zona in short circuit
Check OEM & aftermarket availability for Rain Bird Replacement Sensor / Part:
⚡ Open in Interactive Simulator →
5. Frequently Asked Questions: Rain Bird / Hunter (Riego) Error Code ERR / MV / Zona in short circuit
What does Rain Bird / Hunter (Riego) error code ERR / MV / Zona in short circuit mean?
Rain Bird / Hunter (Riego) ERR / MV / Zona in short circuit: Programmer screen shows 'ERR' (or zone number + ERR/MV) and skips that sector without watering (Programadores of Riego Automatic Rain Bird (ESP-RZXe, ESP-Me, ESP-TM2) and Hunter (X-Core, Pro-C, Eco-Logic)). Multimeter Specs: Irrigation solenoid coil resistance 24V AC (Rain Bird / Hunter): 24 Ω to 55 Ω | Programmer output voltage: 24V - 28V AC.
How do I reset Rain Bird / Hunter (Riego) fault code ERR / MV / Zona in short circuit?
Replace the 24V AC solenoid coil in the area marked ERR in the box and press the forward arrow to clear the warning.
What multimeter values should I check for Rain Bird / Hunter (Riego) code ERR / MV / Zona in short circuit?
Irrigation solenoid coil resistance 24V AC (Rain Bird / Hunter): 24 Ω to 55 Ω | Programmer output voltage: 24V - 28V AC