Heat Pumps (Aerothermal)

Mitsubishi Ecodan Error Codes: Complete List (2 Faults), Causes & Reset

Complete technical directory of all 2 Mitsubishi Ecodan error codes (Heat Pumps (Aerothermal)) with exact meanings, multimeter reference specs, and reset instructions.

Error Code Technical Meaning Multimeter Specs
Mitsubishi Ecodan Code L9 (Bajo flow rate in primary circuit)El mando FTC of the aerotermia Mitsubishi Ecodan muestra el error 'L9' and se detiene la Pump of calorflow rate nominal requerido Mitsubishi Ecodan: 14 a 25 L/min (Salta L9 si cae due to debajo of ~7-9 L/min For / During 15 seg)
Mitsubishi Ecodan U1 / U2 / P6 (pressure Alta Gas / overload outdoor condenser unit)La aerotermia Mitsubishi Ecodan se to with Code 'U1' (Alta pressure of gas in el condensador) or 'U2' in invierno or al hacer ACSpressure switch of alta pressure Mitsubishi Zubadan/Ecodan (63HS): Abre a 4.15 MPa (41.5 bar)