Junkers · 11 Verified Diagnostic Sheets
ESENDEFRIT
Boilers & Heating

Junkers Error Codes: Complete List (11 Faults), Causes & Reset

Complete technical directory of all 11 Junkers error codes (Boilers & Heating) with exact meanings, multimeter reference specs, and reset instructions.

Error Code Technical Meaning Multimeter Specs
Junkers A7Defective hot water (DHW) temperature sensorNTC Junkers at 25°C: ~12 kΩ (at 60°C: ~3.0 kΩ)
Junkers ADAccumulator probe not detectedNTC accumulator resistance at 25°C: 12 kΩ
Junkers b1Valve / Key of codificación (Coding Plug) no detectada due to la main control board (PCB)resistance específica of modelo dentro of the Coding Plug
Junkers C4El flue air pressure switch does NOT open when the fan is at rest (Code 216)pressure switch at rest (idle) (Fan off): open circuit (OL infinite)
Junkers C6The smoke pressure switch does not close or the fan fails (Code 215)Differential pressure switch: Closes at > 65 Pa
Junkers CEInsufficient heating water pressure (Code 207)Nominal pressure: 1.2 - 1.8 bar
Junkers E9Thermal block temperature limiter tripped (Code 224)STB limiter: 0 Ω cold (Cuts at > 105°C)
Junkers EAFlame not detected (Equivalent to code 227)Ionization current: > 2.0 µA | NTC probe at 25°C: 12 kΩ
Junkers F0Internal fault in the electronic board or loose harness (Code 290)Stable mains voltage: 230V AC ±10%
Junkers F7False flame detection with boiler at rest (Code 228)Electrode insulation: Infinity (OL) with respect to ground
Junkers FdButton of Reset pulsado due to error For / During más of 30 seconds seguidos (Code 290)Contacto pulsador frontal Normalmente open (NA)