Junkers Calentador (Hydronext) Β· 3 Verified Diagnostic Sheets
ESENDEFRIT
Boilers & Heating

Junkers Calentador (Hydronext) Error Codes: Complete List (3 Faults), Causes & Reset

Complete technical directory of all 3 Junkers Calentador (Hydronext) error codes (Boilers & Heating) with exact meanings, multimeter reference specs, and reset instructions.

Error Code Technical Meaning Multimeter Specs
Junkers Calentador (Hydronext) C7 / C4Fault / Failure in el Fan or in el pressure switch/sensor of humos of the calentador estanco (No evacúa gases)pressure switch diferencial: open (OL) at rest (idle), closed (0 Ξ©) with Fan in marcha
Junkers Calentador (Hydronext) E9Limitador of temperature of the serpentín (Thermostat of overheat condition > 105°C open)safety limit thermostat serpentín: 0 Ξ© closed in frío
Junkers Calentador (Hydronext) EANo se detecta Flame in el calentador al abrir el grifo of Water caliente (Fault / Failure of Ionization or falta of gas)Current of Ionization Minimum Junkers Hydronext: > 1.5 µA | pressure Butano: 28-30 mbar
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Junkers Calentador Replacement Sensor / Part:

Other Manufacturers & Fault Code Directories