Johnson / Kosner / Giatsu Error Code EE / E9: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Johnson / Kosner / Giatsu EE / E9)
| Manufacturer / Brand | Johnson / Kosner / Giatsu |
|---|---|
| Error Code | EE / E9 |
| System / Category | Air Conditioning |
| Compatible Models | Splits and Ducted Obra Nueva (Electrónica base Midea / Gree) |
| Severity Level | Low Severity · Maintenance Advisory |
| Multimeter Specs | Roof Buoy Switch: Normally Closed (0 Ω) without water |
2. Guided Symptom Troubleshooting Matrix
The drain in the false ceiling of the bathroom has been clogged with sludge and the **safety float buoy** has cut off the air so that the plaster ceiling does not flood. Climb up to the bathroom register, blow hard down the drain pipe into the siphon canister and empty the stagnant water in the tray with a syringe or sponge.
Burnt auxiliary condensate pump.
3. Step-by-Step Multimeter Testing Procedure (EE / E9)
- Safety Power Isolation: Disconnect the Johnson / Kosner / Giatsu unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault EE / E9 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Roof Buoy Switch: Normally Closed (0 Ω) without water.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Johnson / Kosner / Giatsu Error EE / E9
Check OEM & aftermarket availability for Johnson Replacement Sensor / Part:
⚡ Open in Interactive Simulator →
5. Frequently Asked Questions: Johnson / Kosner / Giatsu Error Code EE / E9
What does Johnson / Kosner / Giatsu error code EE / E9 mean?
Johnson / Kosner / Giatsu EE / E9: Condensate tray full: Water level buoy activated (On duct machines) (Splits and Ducted Obra Nueva (Electrónica base Midea / Gree)). Multimeter Specs: Roof Buoy Switch: Normally Closed (0 Ω) without water.
How do I reset Johnson / Kosner / Giatsu fault code EE / E9?
Unclog the drain pipe to the bathroom siphon bottle and empty the water from the tray so that the buoy goes down.
What multimeter values should I check for Johnson / Kosner / Giatsu code EE / E9?
Roof Buoy Switch: Normally Closed (0 Ω) without water