Johnson / Kosner / Giatsu Error Code E1: Meaning, Multimeter Diagnosis & Fix

Fault code E1 on Johnson / Kosner / Giatsu units (Splits and Ducted Obra Nueva (Electrónica base Midea / Gree)) indicates: Communication error between the indoor machine (ducts/split) and the outdoor unit (or High Pressure in Gree). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Air Conditioning subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Johnson / Kosner / Giatsu E1)

Manufacturer / BrandJohnson / Kosner / Giatsu
Error CodeE1
System / CategoryAir Conditioning
Compatible ModelsSplits and Ducted Obra Nueva (Electrónica base Midea / Gree)
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsN-S communication signal: 0V to 50V DC variable | High pressure switch: 0 Ω closed at rest

2. Guided Symptom Troubleshooting Matrix

🔎 Do you have a duct machine in the false ceiling of the bathroom and the wall control marked 'E1'?
✓ Scenario A: Yes (Confirmed)

1) Lower the 'Climate/Air' automatic on the electrical panel for **5 full minutes** and raise it again. 2) If your machine is a Midea base (terminals L, N, S), it is a communication failure on the S cable. If your machine is a Gree base, E1 means **high pressure switch trip** due to having a dirty outdoor battery or the roof filters being clogged.

✕ Scenario B: No (Not Present)

Clean the mesh filters that fit into the back of the machine on the bathroom ceiling.

3. Step-by-Step Multimeter Testing Procedure (E1)

  1. Safety Power Isolation: Disconnect the Johnson / Kosner / Giatsu unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault E1 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: N-S communication signal: 0V to 50V DC variable | High pressure switch: 0 Ω closed at rest.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Johnson / Kosner / Giatsu Error E1

🔄 Johnson / Kosner / Giatsu E1 Reset: Cut power for 5 minutes from the electrical panel and clean return filters.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (Pressure Switch)?

Check OEM & aftermarket availability for Johnson Pressure Switch:

Want to use the interactive diagnostic wizard or electrical calculators for Johnson / Kosner / Giatsu E1?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Johnson / Kosner / Giatsu Error Code E1

What does Johnson / Kosner / Giatsu error code E1 mean?

Johnson / Kosner / Giatsu E1: Communication error between the indoor machine (ducts/split) and the outdoor unit (or High Pressure in Gree) (Splits and Ducted Obra Nueva (Electrónica base Midea / Gree)). Multimeter Specs: N-S communication signal: 0V to 50V DC variable | High pressure switch: 0 Ω closed at rest.

How do I reset Johnson / Kosner / Giatsu fault code E1?

Cut power for 5 minutes from the electrical panel and clean return filters.

What multimeter values should I check for Johnson / Kosner / Giatsu code E1?

N-S communication signal: 0V to 50V DC variable | High pressure switch: 0 Ω closed at rest