Hermann / Manaut Error Code E10 / F10: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Hermann / Manaut E10 / F10)
| Manufacturer / Brand | Hermann / Manaut |
|---|---|
| Error Code | E10 / F10 |
| System / Category | Boilers & Heating |
| Compatible Models | Boilers Hermann Micra 3, Micra 4, Supermicra, Habitat and Manaut Myto, Minox |
| Severity Level | Low Severity · Maintenance Advisory |
| Multimeter Specs | Minimum water pressure switch: Closes contact (0 Ω) when exceeding 0.7 bar |
2. Guided Symptom Troubleshooting Matrix
Open the lower fill cock until the pressure gauge reads **1.2 - 1.5 bar** and close it. If the pressure gauge already reads 1.5 bar but E10 continues to appear, the small **hydraulic pressure switch (brass/plastic part with 2 cables)** has the internal hole clogged with lime.
Disconnect the 2 cables from the water pressure switch and join them for a second to check if the E10 disappears.
3. Step-by-Step Multimeter Testing Procedure (E10 / F10)
- Safety Power Isolation: Disconnect the Hermann / Manaut unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault E10 / F10 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Minimum water pressure switch: Closes contact (0 Ω) when exceeding 0.7 bar.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Hermann / Manaut Error E10 / F10
Check OEM & aftermarket availability for Hermann Pressure Switch:
⚡ Open in Interactive Simulator →
5. Frequently Asked Questions: Hermann / Manaut Error Code E10 / F10
What does Hermann / Manaut error code E10 / F10 mean?
Hermann / Manaut E10 / F10: Lack of water pressure in the heating circuit (Hydraulic pressure switch open < 0.5 bar) (Boilers Hermann Micra 3, Micra 4, Supermicra, Habitat and Manaut Myto, Minox). Multimeter Specs: Minimum water pressure switch: Closes contact (0 Ω) when exceeding 0.7 bar.
How do I reset Hermann / Manaut fault code E10 / F10?
Increase the water pressure to 1.5 bar by opening the lower fill cock.
What multimeter values should I check for Hermann / Manaut code E10 / F10?
Minimum water pressure switch: Closes contact (0 Ω) when exceeding 0.7 bar