Hermann / Manaut Error Code E01 / E02: Meaning, Multimeter Diagnosis & Fix

Fault code E01 / E02 on Hermann / Manaut units (Boilers Hermann Micra 3, Micra 4, Supermicra, Habitat and Manaut Myto, Minox) indicates: Blocking due to lack of flame ignition (E01) or tripping of the overtemperature thermostat (E02). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Hermann / Manaut E01 / E02)

Manufacturer / BrandHermann / Manaut
Error CodeE01 / E02
System / CategoryBoilers & Heating
Compatible ModelsBoilers Hermann Micra 3, Micra 4, Supermicra, Habitat and Manaut Myto, Minox
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsHermann/Manaut NTC probes at 25°C: 10 kΩ

2. Guided Symptom Troubleshooting Matrix

🔎 Does the boiler mark E01 after sparking or E02 after suddenly heating up?
✓ Scenario A: Yes (Confirmed)

For **E01**: check gas supply and clean the ionization spark plug. For **E02**: Unlock the circulator pump rotor by removing the center plug with a flat screwdriver.

✕ Scenario B: No (Not Present)

Press and hold the **Flame crossed out (Reset)** button for 3 seconds.

3. Step-by-Step Multimeter Testing Procedure (E01 / E02)

  1. Safety Power Isolation: Disconnect the Hermann / Manaut unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault E01 / E02 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Hermann/Manaut NTC probes at 25°C: 10 kΩ.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Hermann / Manaut Error E01 / E02

🔄 Hermann / Manaut E01 / E02 Reset: Press the 'Reset' key for 3 seconds after checking the gas supply or unlocking the pump.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for Hermann NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for Hermann / Manaut E01 / E02?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Hermann / Manaut Error Code E01 / E02

What does Hermann / Manaut error code E01 / E02 mean?

Hermann / Manaut E01 / E02: Blocking due to lack of flame ignition (E01) or tripping of the overtemperature thermostat (E02) (Boilers Hermann Micra 3, Micra 4, Supermicra, Habitat and Manaut Myto, Minox). Multimeter Specs: Hermann/Manaut NTC probes at 25°C: 10 kΩ.

How do I reset Hermann / Manaut fault code E01 / E02?

Press the 'Reset' key for 3 seconds after checking the gas supply or unlocking the pump.

What multimeter values should I check for Hermann / Manaut code E01 / E02?

Hermann/Manaut NTC probes at 25°C: 10 kΩ