Energía Solar Medium Severity · Protection Mode

Huawei SUN2000 / SolarEdge / SMA Error Code Error 2064 / Fault / Failure Smart Meter: Meaning, Multimeter Diagnosis & Fix

Fault code Error 2064 / Fault / Failure Smart Meter on Huawei SUN2000 / SolarEdge / SMA units (Hybrid Solar Inverters Huawei SUN2000 (2KTL-10KTL L1/M1), Battery LUNA2000, SolarEdge HD-Wave and SMA Sunny Boy) indicates: Equipment anomaly or loss of RS485 communication with the bidirectional meter (Smart Power Sensor DDSU666-H / DTSU666-H). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Energía Solar subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Huawei SUN2000 / SolarEdge / SMA Error 2064 / Fault / Failure Smart Meter)

Manufacturer / BrandHuawei SUN2000 / SolarEdge / SMA
Error CodeError 2064 / Fault / Failure Smart Meter
System / CategoryEnergía Solar
Compatible ModelsHybrid Solar Inverters Huawei SUN2000 (2KTL-10KTL L1/M1), Battery LUNA2000, SolarEdge HD-Wave and SMA Sunny Boy
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsHuawei DDSU666-H meter default Modbus address: Address 11, Baudrate 9600 bps

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž In the FusionSolar app, do you not see the home consumption (it appears gray) or is the LUNA2000 battery not charging/discharging?
βœ“ Scenario A: Yes (Confirmed)

**RS485** communication has been interrupted between pins **7 and 9** of the COM connector of the Huawei inverter and screws **24 and 25** of the Chint DDSU666-H meter in your electrical panel: 1) Check that the data cable has not come loose when inserting the panel cover. 2) Verify that the current clamp (CT) is connected to the screws **5 and 6** of the meter with the arrow pointing towards the interior of the house (`K -> L`).

βœ• Scenario B: No (Not Present)

Retighten the wires RS485_A (pin 24) and RS485_B (pin 25) on the smart meter in the general panel.

3. Step-by-Step Multimeter Testing Procedure (Error 2064 / Fault / Failure Smart Meter)

  1. Safety Power Isolation: Disconnect the Huawei SUN2000 / SolarEdge / SMA unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Error 2064 / Fault / Failure Smart Meter for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Huawei DDSU666-H meter default Modbus address: Address 11, Baudrate 9600 bps.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Huawei SUN2000 / SolarEdge / SMA Error Error 2064 / Fault / Failure Smart Meter

πŸ”„ Huawei SUN2000 / SolarEdge / SMA Error 2064 / Fault / Failure Smart Meter Reset: Check RS485 twisted pair connection between inverter (pins 7 and 9 in L1) and DDSU666-H meter (terminals 24 and 25).
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Huawei SUN2000 Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Huawei SUN2000 / SolarEdge / SMA Error 2064 / Fault / Failure Smart Meter?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Huawei SUN2000 / SolarEdge / SMA Error Code Error 2064 / Fault / Failure Smart Meter

What does Huawei SUN2000 / SolarEdge / SMA error code Error 2064 / Fault / Failure Smart Meter mean?

Huawei SUN2000 / SolarEdge / SMA Error 2064 / Fault / Failure Smart Meter: Equipment anomaly or loss of RS485 communication with the bidirectional meter (Smart Power Sensor DDSU666-H / DTSU666-H) (Hybrid Solar Inverters Huawei SUN2000 (2KTL-10KTL L1/M1), Battery LUNA2000, SolarEdge HD-Wave and SMA Sunny Boy). Multimeter Specs: Huawei DDSU666-H meter default Modbus address: Address 11, Baudrate 9600 bps.

How do I reset Huawei SUN2000 / SolarEdge / SMA fault code Error 2064 / Fault / Failure Smart Meter?

Check RS485 twisted pair connection between inverter (pins 7 and 9 in L1) and DDSU666-H meter (terminals 24 and 25).

What multimeter values should I check for Huawei SUN2000 / SolarEdge / SMA code Error 2064 / Fault / Failure Smart Meter?

Huawei DDSU666-H meter default Modbus address: Address 11, Baudrate 9600 bps