Fagor Error Codes: Complete List (6 Faults), Causes & Reset

Complete technical directory of all 6 Fagor error codes (Boilers & Heating) with exact meanings, multimeter reference specs, and reset instructions.

Error Code Technical Meaning Multimeter Specs
Fagor F01Ignition failure / No flame detected (1 red flash)Gas valve coil: ~140 Ω | Ionization > 1.5 µA
Fagor F02Primary circuit overheating (> 98°C)Klixon thermostat: 0 Ω closed
Fagor F03Anomaly in the evacuation of burned gasesExtractor winding resistance: 50-85 Ω
Fagor F04Lack of water pressure in the circuit (< 0.5 bar)Recommended cold pressure: 1.5 bar
Fagor F1 / 1 LED Rojo (Fault / Failure Flame)Lockout / Blockage due to falta of ignition of Flame in el burner of Boiler Fagor (Code F1)NTC thermistor probe Fagor a 25°C: 10 kΩ
Fagor F9 / 4 LEDs (Falta of Water)pressure of Water insuficiente in el circuito of calefacción (< 0.5 bar - Code F9 in Fagor)pressure switch of Water Fagor: 0 Ω closed with pressure > 0.7 bar