Cointra Β· 4 Verified Diagnostic Sheets
ESENDEFRIT
Boilers & Heating

Cointra Error Codes: Complete List (4 Faults), Causes & Reset

Complete technical directory of all 4 Cointra error codes (Boilers & Heating) with exact meanings, multimeter reference specs, and reset instructions.

Error Code Technical Meaning Multimeter Specs
Cointra A01Lockout due to lack of flame (Ignition failure)Single electrode (ignition/ionization) | Current > 1.5 µA | Neutral-Ground Voltage < 2V
Cointra A03Protection trip due to overtemperature (> 98°C)Dual NTC probe at 25°C: 10 kΞ© on both pairs of pins
Cointra F05Failure in the smoke pressure switch or extractor fanAir pressure switch: 0 Ξ© closed with active fan
Cointra F37Insufficient water pressure in the circuit (< 0.5 bar)Optimal pressure: 1.2 - 1.5 bar | Transducer signal: 0.5V to 4.5V DC
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Cointra Replacement Sensor / Part: