Cillit (Descalcificadores) Error Code Pierde Water Continua due to el Tubo of Drain (Juntas / Pistón): Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Cillit (Descalcificadores) Pierde Water Continua due to el Tubo of Drain (Juntas / Pistón))
| Manufacturer / Brand | Cillit (Descalcificadores) |
|---|---|
| Error Code | Pierde Water Continua due to el Tubo of Drain (Juntas / Pistón) |
| System / Category | Boilers & Heating |
| Compatible Models | Descalcificadores and Equipos of Osmosis Cillit (Cillit Parat, Cillit Bonaqua, Cillit Access, Cillit Aqua - Grupo BWT) |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | Normal water consumption in Service position: 0.0 L/h (Water should only be evacuated to the drain during the ~60 min of night regeneration) |
2. Guided Symptom Troubleshooting Matrix
The **Teflon center piston and gasket and spacer package (or the two ceramic discs)** inside the upper valve have been scratched with rust from the pipes and do not seal in the *Service* position. If you leave your ear glued to the drain pipe and hear *'sssssh'* of water passing by, close the **Rear By-Pass** of the softener and replace the **gasket and piston kit (or ceramic cartridge)** of the head.
Close the rear bypass while replacing the seal/piston kit to avoid wasting hundreds of liters of water into the sewer.
3. Step-by-Step Multimeter Testing Procedure (Pierde Water Continua due to el Tubo of Drain (Juntas / Pistón))
- Safety Power Isolation: Disconnect the Cillit (Descalcificadores) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault Pierde Water Continua due to el Tubo of Drain (Juntas / Pistón) for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Normal water consumption in Service position: 0.0 L/h (Water should only be evacuated to the drain during the ~60 min of night regeneration).
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Cillit (Descalcificadores) Error Pierde Water Continua due to el Tubo of Drain (Juntas / Pistón)
Check OEM & aftermarket availability for Cillit Drain Pump:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Cillit (Descalcificadores) Error Code Pierde Water Continua due to el Tubo of Drain (Juntas / Pistón)
What does Cillit (Descalcificadores) error code Pierde Water Continua due to el Tubo of Drain (Juntas / Pistón) mean?
Cillit (Descalcificadores) Pierde Water Continua due to el Tubo of Drain (Juntas / Pistón): The Cillit softener is in normal operating hours (without regenerating), but you hear a continuous stream of water falling into the drain 24 hours a day. (Descalcificadores and Equipos of Osmosis Cillit (Cillit Parat, Cillit Bonaqua, Cillit Access, Cillit Aqua - Grupo BWT)). Multimeter Specs: Normal water consumption in Service position: 0.0 L/h (Water should only be evacuated to the drain during the ~60 min of night regeneration).
How do I reset Cillit (Descalcificadores) fault code Pierde Water Continua due to el Tubo of Drain (Juntas / Pistón)?
Check that the head has completed its rotation to the 'Service' position; If it continues to leak into the drain, replace the piston and gasket cage kit.
What multimeter values should I check for Cillit (Descalcificadores) code Pierde Water Continua due to el Tubo of Drain (Juntas / Pistón)?
Normal water consumption in Service position: 0.0 L/h (Water should only be evacuated to the drain during the ~60 min of night regeneration)