Cillit (Descalcificadores) Error Code Depósito of Sal Rebosa of Water until Arriba (No Aspira Salmuera): Meaning, Multimeter Diagnosis & Fix

Fault code Depósito of Sal Rebosa of Water until Arriba (No Aspira Salmuera) on Cillit (Descalcificadores) units (Descalcificadores and Equipos of Osmosis Cillit (Cillit Parat, Cillit Bonaqua, Cillit Access, Cillit Aqua - Grupo BWT)) indicates: You open the lid of your Cillit descaler and see that the salt bucket is flooded with water up to the top edge.. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Cillit (Descalcificadores) Depósito of Sal Rebosa of Water until Arriba (No Aspira Salmuera))

Manufacturer / BrandCillit (Descalcificadores)
Error CodeDepósito of Sal Rebosa of Water until Arriba (No Aspira Salmuera)
System / CategoryBoilers & Heating
Compatible ModelsDescalcificadores and Equipos of Osmosis Cillit (Cillit Parat, Cillit Bonaqua, Cillit Access, Cillit Aqua - Grupo BWT)
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsIf a single air bubble enters through the brine tube nut, the Venturi effect is broken and the head cannot suck the water from the tank.

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Instead of there being only an inch of water at the bottom of the salt tank, is it filled to the top with water?
βœ“ Scenario A: Yes (Confirmed)

In a normal regeneration cycle, the softener first **sucks up all the salt water (Suction/Brine Phase)** and at the end adds a few liters of clean water to prepare for the next time. If it floods every week: **it has added water at the end but could NOT suck it at the beginning because the Venturi Injector in the head is clogged with lime/mud or the thin tube that goes from the head to the brine rod takes in air through the nut (loose fitting)**.

βœ• Scenario B: No (Not Present)

Clean the Venturi injector and the mesh filter from its cover in the upper head, tighten the two nuts of the transparent/black brine tube and set the head manually to **`BRINE DRAW / ASPIRATION`** step for 20 minutes so that all the excess water is drunk.

3. Step-by-Step Multimeter Testing Procedure (Depósito of Sal Rebosa of Water until Arriba (No Aspira Salmuera))

  1. Safety Power Isolation: Disconnect the Cillit (Descalcificadores) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Depósito of Sal Rebosa of Water until Arriba (No Aspira Salmuera) for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: If a single air bubble enters through the brine tube nut, the Venturi effect is broken and the head cannot suck the water from the tank..
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Cillit (Descalcificadores) Error Depósito of Sal Rebosa of Water until Arriba (No Aspira Salmuera)

πŸ”„ Cillit (Descalcificadores) Depósito of Sal Rebosa of Water until Arriba (No Aspira Salmuera) Reset: Clean the Venturi injector and the head mesh filter, tighten the brine tube fittings so that it does not take in air and empty the excess in Suction mode.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Cillit Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Cillit (Descalcificadores) Depósito of Sal Rebosa of Water until Arriba (No Aspira Salmuera)?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Cillit (Descalcificadores) Error Code Depósito of Sal Rebosa of Water until Arriba (No Aspira Salmuera)

What does Cillit (Descalcificadores) error code Depósito of Sal Rebosa of Water until Arriba (No Aspira Salmuera) mean?

Cillit (Descalcificadores) Depósito of Sal Rebosa of Water until Arriba (No Aspira Salmuera): You open the lid of your Cillit descaler and see that the salt bucket is flooded with water up to the top edge. (Descalcificadores and Equipos of Osmosis Cillit (Cillit Parat, Cillit Bonaqua, Cillit Access, Cillit Aqua - Grupo BWT)). Multimeter Specs: If a single air bubble enters through the brine tube nut, the Venturi effect is broken and the head cannot suck the water from the tank..

How do I reset Cillit (Descalcificadores) fault code Depósito of Sal Rebosa of Water until Arriba (No Aspira Salmuera)?

Clean the Venturi injector and the head mesh filter, tighten the brine tube fittings so that it does not take in air and empty the excess in Suction mode.

What multimeter values should I check for Cillit (Descalcificadores) code Depósito of Sal Rebosa of Water until Arriba (No Aspira Salmuera)?

If a single air bubble enters through the brine tube nut, the Venturi effect is broken and the head cannot suck the water from the tank.