Cadel Error Code Alarma 'No Acc' / 'Alar No Fire' (Fault / Failure of ignition): Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Cadel Alarma 'No Acc' / 'Alar No Fire' (Fault / Failure of ignition))
| Manufacturer / Brand | Cadel |
|---|---|
| Error Code | Alarma 'No Acc' / 'Alar No Fire' (Fault / Failure of ignition) |
| System / Category | Boilers & Heating |
| Compatible Models | Estufas of Pellets Italianas Cadel / FreePoint (Cristal, Sweet, Prince, Spirit, Sfera, Venus, Rondò - Board / Plate Micronova) |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | Cadel stove ignition resistor (Micronova): Diameter 9.5 mm, 250W - 280W (~190 Ω) |
2. Guided Symptom Troubleshooting Matrix
The **Micronova** electronic system has not detected a flame: 1) Empty the basket of unburned pellets. 2) Make sure that the iron basket is well seated in its socket without being raised by ash under the edge (if it is raised by 2 mm, the hot air from the spark plug escapes outside instead of passing through the pellets). 3) If the spark plug does not turn red in the first 3 minutes, change the **spark plug (9.5 mm x 140/150 mm, 280W)**.
Clear the alarm by holding **Button 4 (On/Off)** for 3 seconds.
3. Step-by-Step Multimeter Testing Procedure (Alarma 'No Acc' / 'Alar No Fire' (Fault / Failure of ignition))
- Safety Power Isolation: Disconnect the Cadel unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault Alarma 'No Acc' / 'Alar No Fire' (Fault / Failure of ignition) for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Cadel stove ignition resistor (Micronova): Diameter 9.5 mm, 250W - 280W (~190 Ω).
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Cadel Error Alarma 'No Acc' / 'Alar No Fire' (Fault / Failure of ignition)
Check OEM & aftermarket availability for Cadel Ignition & Flame Electrode:
⚡ Open in Interactive Simulator →
5. Frequently Asked Questions: Cadel Error Code Alarma 'No Acc' / 'Alar No Fire' (Fault / Failure of ignition)
What does Cadel error code Alarma 'No Acc' / 'Alar No Fire' (Fault / Failure of ignition) mean?
Cadel Alarma 'No Acc' / 'Alar No Fire' (Fault / Failure of ignition): On the 1-line display of your Cadel or FreePoint stove, 'Alar No Acc' (Mancata Accensione) flashes and beeps. (Estufas of Pellets Italianas Cadel / FreePoint (Cristal, Sweet, Prince, Spirit, Sfera, Venus, Rondò - Board / Plate Micronova)). Multimeter Specs: Cadel stove ignition resistor (Micronova): Diameter 9.5 mm, 250W - 280W (~190 Ω).
How do I reset Cadel fault code Alarma 'No Acc' / 'Alar No Fire' (Fault / Failure of ignition)?
Empty the brazier, seat the basket correctly on its clean base and replace the ignition resistance if it does not glow.
What multimeter values should I check for Cadel code Alarma 'No Acc' / 'Alar No Fire' (Fault / Failure of ignition)?