Engineering Review: 2026-11-21 Β· SAE J2012 / IEC / OEM Verified
ESENDEFRIT
Boilers & Heating High Severity · Safety Lockout

Cadel Error Code Alarma 'Dep Sic' / 'Alar Dep / Sic Fail' (Seguridad Thermal or Humos): Meaning, Multimeter Diagnosis & Fix

Fault code Alarma 'Dep Sic' / 'Alar Dep / Sic Fail' (Seguridad Thermal or Humos) on Cadel units (Estufas of Pellets Italianas Cadel / FreePoint (Cristal, Sweet, Prince, Spirit, Sfera, Venus, Rondò - Board / Plate Micronova)) indicates: 'Alar Dep' or 'Sic Fail' appears on the Cadel screen and the auger stops feeding pellets. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Cadel Alarma 'Dep Sic' / 'Alar Dep / Sic Fail' (Seguridad Thermal or Humos))

Manufacturer / BrandCadel
Error CodeAlarma 'Dep Sic' / 'Alar Dep / Sic Fail' (Seguridad Thermal or Humos)
System / CategoryBoilers & Heating
Compatible ModelsEstufas of Pellets Italianas Cadel / FreePoint (Cristal, Sweet, Prince, Spirit, Sfera, Venus, Rondò - Board / Plate Micronova)
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsMicronova plates technical menu key (Cadel / Bronpi / Eva Calor) to delete 'Serv' notice: Code A9

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does the flame go out by itself and 'Alar Dep' or 'Sic Fail' appears on the screen?
βœ“ Scenario A: Yes (Confirmed)

On **Cadel** Micronova hobs: the smoke pressure switch (`Dep`) and the rear safety thermostat with button (`Sic`) are connected in the same cable in series: 1) Look behind the stove, unscrew the round black cap of the **safety thermostat** and press its central button. 2) Clean the dust accumulated on the blades of the **ambient air fan** (if the fan that blows hot air into the living room has lint, the stove overheats inside and triggers 'Sic Fail') and clean the 'T' of the chimney.

βœ• Scenario B: No (Not Present)

**How ​​to remove the annoying 'Serv' sign (Service Hours)**: Go to *Menu -> Technical Settings (`M8` / `M9`)* -> enter the password **`A9`** -> select *Reset Partial Hours*.

3. Step-by-Step Multimeter Testing Procedure (Alarma 'Dep Sic' / 'Alar Dep / Sic Fail' (Seguridad Thermal or Humos))

  1. Safety Power Isolation: Disconnect the Cadel unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Alarma 'Dep Sic' / 'Alar Dep / Sic Fail' (Seguridad Thermal or Humos) for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Micronova plates technical menu key (Cadel / Bronpi / Eva Calor) to delete 'Serv' notice: Code A9.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Cadel Error Alarma 'Dep Sic' / 'Alar Dep / Sic Fail' (Seguridad Thermal or Humos)

πŸ”„ Cadel Alarma 'Dep Sic' / 'Alar Dep / Sic Fail' (Seguridad Thermal or Humos) Reset: Reset the rear thermostat button under its screw cap, clean the smoke outlet and hold Off for 3 seconds.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Cadel Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Cadel Alarma 'Dep Sic' / 'Alar Dep / Sic Fail' (Seguridad Thermal or Humos)?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Cadel Error Code Alarma 'Dep Sic' / 'Alar Dep / Sic Fail' (Seguridad Thermal or Humos)

What does Cadel error code Alarma 'Dep Sic' / 'Alar Dep / Sic Fail' (Seguridad Thermal or Humos) mean?

Cadel Alarma 'Dep Sic' / 'Alar Dep / Sic Fail' (Seguridad Thermal or Humos): 'Alar Dep' or 'Sic Fail' appears on the Cadel screen and the auger stops feeding pellets (Estufas of Pellets Italianas Cadel / FreePoint (Cristal, Sweet, Prince, Spirit, Sfera, Venus, Rondò - Board / Plate Micronova)). Multimeter Specs: Micronova plates technical menu key (Cadel / Bronpi / Eva Calor) to delete 'Serv' notice: Code A9.

How do I reset Cadel fault code Alarma 'Dep Sic' / 'Alar Dep / Sic Fail' (Seguridad Thermal or Humos)?

Reset the rear thermostat button under its screw cap, clean the smoke outlet and hold Off for 3 seconds.

What multimeter values should I check for Cadel code Alarma 'Dep Sic' / 'Alar Dep / Sic Fail' (Seguridad Thermal or Humos)?

Micronova plates technical menu key (Cadel / Bronpi / Eva Calor) to delete 'Serv' notice: Code A9