Buderus Error Code 6A: Meaning, Multimeter Diagnosis & Fix

Fault code 6A on Buderus units (Logamax Plus GB072, GB122, GB162, GB172, Logano (Grupo Bosch)) indicates: No flame detected after the 4º ignition attempt (Lockout / Blockage of ignition - Code 227). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Buderus 6A)

Manufacturer / BrandBuderus
Error Code6A
System / CategoryBoilers & Heating
Compatible ModelsLogamax Plus GB072, GB122, GB162, GB172, Logano (Grupo Bosch)
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsCurrent of Ionization Minimum Buderus: > 2.0 µA

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does Buderus error code 6A return immediately after a full power cycle even when main supply voltage is stable?
βœ“ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (No flame detected after the 4º ignition attempt (Lockout / Blockage of ignition - Code 227)). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: Current of Ionization Minimum Buderus: > 2.0 µA. If it reads open circuit (OL) or dead short, replace the faulty part.

βœ• Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: Press and hold the button 'Reset' until the display shows 'rE'.

3. Step-by-Step Multimeter Testing Procedure (6A)

  1. Safety Power Isolation: Disconnect the Buderus unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault 6A for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Current of Ionization Minimum Buderus: > 2.0 µA.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Buderus Error 6A

πŸ”„ Buderus 6A Reset: Press and hold the button 'Reset' until the display shows 'rE'.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Ignition & Flame Electrode)?

Check OEM & aftermarket availability for Buderus Ignition & Flame Electrode:

Want to use the interactive diagnostic wizard or electrical calculators for Buderus 6A?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Buderus Error Code 6A

What does Buderus error code 6A mean?

Buderus 6A: No flame detected after the 4º ignition attempt (Lockout / Blockage of ignition - Code 227) (Logamax Plus GB072, GB122, GB162, GB172, Logano (Grupo Bosch)). Multimeter Specs: Current of Ionization Minimum Buderus: > 2.0 µA.

How do I reset Buderus fault code 6A?

Press and hold the button 'Reset' until the display shows 'rE'.

What multimeter values should I check for Buderus code 6A?

Current of Ionization Minimum Buderus: > 2.0 µA