Buderus Error Code 4C / 0Y: Meaning, Multimeter Diagnosis & Fix

Fault code 4C / 0Y on Buderus units (Logamax Plus GB072, GB122, GB162, GB172, Logano (Grupo Bosch)) indicates: overheat condition in el bloque Thermal or disparo of the limitador of gases (> 95°C). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Buderus 4C / 0Y)

Manufacturer / BrandBuderus
Error Code4C / 0Y
System / CategoryBoilers & Heating
Compatible ModelsLogamax Plus GB072, GB122, GB162, GB172, Logano (Grupo Bosch)
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsNTC thermistor probe impulsión Buderus a 25°C: 12 kΩ

2. Guided Symptom Troubleshooting Matrix

🔎 Does Buderus error code 4C / 0Y return immediately after a full power cycle even when main supply voltage is stable?
✓ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (overheat condition in el bloque Thermal or disparo of the limitador of gases (> 95°C)). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: NTC thermistor probe impulsión Buderus a 25°C: 12 kΩ. If it reads open circuit (OL) or dead short, replace the faulty part.

✕ Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: Dejar enfriar, purgar Air and Press and hold 'Reset'.

3. Step-by-Step Multimeter Testing Procedure (4C / 0Y)

  1. Safety Power Isolation: Disconnect the Buderus unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault 4C / 0Y for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: NTC thermistor probe impulsión Buderus a 25°C: 12 kΩ.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Buderus Error 4C / 0Y

🔄 Buderus 4C / 0Y Reset: Dejar enfriar, purgar Air and Press and hold 'Reset'.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for Buderus NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for Buderus 4C / 0Y?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Buderus Error Code 4C / 0Y

What does Buderus error code 4C / 0Y mean?

Buderus 4C / 0Y: overheat condition in el bloque Thermal or disparo of the limitador of gases (> 95°C) (Logamax Plus GB072, GB122, GB162, GB172, Logano (Grupo Bosch)). Multimeter Specs: NTC thermistor probe impulsión Buderus a 25°C: 12 kΩ.

How do I reset Buderus fault code 4C / 0Y?

Dejar enfriar, purgar Air and Press and hold 'Reset'.

What multimeter values should I check for Buderus code 4C / 0Y?

NTC thermistor probe impulsión Buderus a 25°C: 12 kΩ