BSV Electronic Error Code Pump Peristáltica of pH No Chupa Ácido (Tubo Santoprene): Meaning, Multimeter Diagnosis & Fix

Fault code Pump Peristáltica of pH No Chupa Ácido (Tubo Santoprene) on BSV Electronic units (Cloradores Salinos BSV (BS Pool, EVO Basic, EVO Auto, Smart, Touch, N-BSSalt)) indicates: The wheel of the pH dosing pump of your BSV chlorinator spins but the pH reducing liquid does not go up the tube from the bottle. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Pools & Lawn Mowers subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (BSV Electronic Pump Peristáltica of pH No Chupa Ácido (Tubo Santoprene))

Manufacturer / BrandBSV Electronic
Error CodePump Peristáltica of pH No Chupa Ácido (Tubo Santoprene)
System / CategoryPools & Lawn Mowers
Compatible ModelsCloradores Salinos BSV (BS Pool, EVO Basic, EVO Auto, Smart, Touch, N-BSSalt)
Severity LevelLow Severity · Maintenance Advisory
Multimeter SpecsStandard peristaltic pH pump internal tube: Santoprene 4x6 mm or 5x8 mm with fittings

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Do you see the rollers of the acid pump rotating but the transparent tube has air and the liquid does not rise?
βœ“ Scenario A: Yes (Confirmed)

Three €5 wear parts that fail every 2 summers in all peristaltic pool pumps: 1) **The white flexible inner tube (Santoprene tube) that the rollers crush has become flat or has a pore**: open the transparent cover of the pump and change the Santoprene tube (~€7). 2) **The injection valve in the pipe (fitting with rubber band *Duck Bill / Lip*)** is clogged with dry white lime. 3) The leaded filter at the bottom of the bottle is out of the liquid.

βœ• Scenario B: No (Not Present)

Change the Santoprene peristaltic tube every 2 seasons to prevent it from cracking and acid staining the wall.

3. Step-by-Step Multimeter Testing Procedure (Pump Peristáltica of pH No Chupa Ácido (Tubo Santoprene))

  1. Safety Power Isolation: Disconnect the BSV Electronic unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Pump Peristáltica of pH No Chupa Ácido (Tubo Santoprene) for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Standard peristaltic pH pump internal tube: Santoprene 4x6 mm or 5x8 mm with fittings.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear BSV Electronic Error Pump Peristáltica of pH No Chupa Ácido (Tubo Santoprene)

πŸ”„ BSV Electronic Pump Peristáltica of pH No Chupa Ácido (Tubo Santoprene) Reset: Replace the internal elastic Santoprene tube of the peristaltic pump and clean the lip valve (duckbill) on the injection collar.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for BSV Electronic Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for BSV Electronic Pump Peristáltica of pH No Chupa Ácido (Tubo Santoprene)?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: BSV Electronic Error Code Pump Peristáltica of pH No Chupa Ácido (Tubo Santoprene)

What does BSV Electronic error code Pump Peristáltica of pH No Chupa Ácido (Tubo Santoprene) mean?

BSV Electronic Pump Peristáltica of pH No Chupa Ácido (Tubo Santoprene): The wheel of the pH dosing pump of your BSV chlorinator spins but the pH reducing liquid does not go up the tube from the bottle (Cloradores Salinos BSV (BS Pool, EVO Basic, EVO Auto, Smart, Touch, N-BSSalt)). Multimeter Specs: Standard peristaltic pH pump internal tube: Santoprene 4x6 mm or 5x8 mm with fittings.

How do I reset BSV Electronic fault code Pump Peristáltica of pH No Chupa Ácido (Tubo Santoprene)?

Replace the internal elastic Santoprene tube of the peristaltic pump and clean the lip valve (duckbill) on the injection collar.

What multimeter values should I check for BSV Electronic code Pump Peristáltica of pH No Chupa Ácido (Tubo Santoprene)?

Standard peristaltic pH pump internal tube: Santoprene 4x6 mm or 5x8 mm with fittings