Engineering Review: 2026-11-21 Β· SAE J2012 / IEC / OEM Verified
ESENDEFRIT
Pools & Lawn Mowers High Severity · Safety Lockout

BSV Electronic Error Code Alarma 'Falta of Sal / Célula Gastada' (BSV EVO): Meaning, Multimeter Diagnosis & Fix

Fault code Alarma 'Falta of Sal / Célula Gastada' (BSV EVO) on BSV Electronic units (Cloradores Salinos BSV (BS Pool, EVO Basic, EVO Auto, Smart, Touch, N-BSSalt)) indicates: A Low Conductivity / Lack of Salt warning appears on the BSV chlorinator screen or it does not reach the selected grams/hour. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Pools & Lawn Mowers subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (BSV Electronic Alarma 'Falta of Sal / Célula Gastada' (BSV EVO))

Manufacturer / BrandBSV Electronic
Error CodeAlarma 'Falta of Sal / Célula Gastada' (BSV EVO)
System / CategoryPools & Lawn Mowers
Compatible ModelsCloradores Salinos BSV (BS Pool, EVO Basic, EVO Auto, Smart, Touch, N-BSSalt)
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsEstimated useful life of the original BSV cell: 5,000 to 10,000 hours depending on the calcium hardness of the water

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Is your BSV EVO salt chlorinator not increasing to 100% production and signaling a salt or cell alarm?
βœ“ Scenario A: Yes (Confirmed)

1) Check the **water temperature and grams of salt** in the information menu: BSV equipment works optimally at **4 - 5 g/l of salt**. 2) If the salt is correct, remove the titanium cartridge from the transparent glass and remove the white calcareous scale between the sheets by immersing it in diluted pH reducer. 3) If the equipment is more than 4-5 summers old and when cleaning the cell it still does not reach the nominal amperage (e.g. it only reaches 2A instead of 5A), the BSV electrode has reached the end of its useful life.

βœ• Scenario B: No (Not Present)

Also check that the upper rubber plug of the cell does not have moisture rusting the threaded rods.

3. Step-by-Step Multimeter Testing Procedure (Alarma 'Falta of Sal / Célula Gastada' (BSV EVO))

  1. Safety Power Isolation: Disconnect the BSV Electronic unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Alarma 'Falta of Sal / Célula Gastada' (BSV EVO) for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Estimated useful life of the original BSV cell: 5,000 to 10,000 hours depending on the calcium hardness of the water.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear BSV Electronic Error Alarma 'Falta of Sal / Célula Gastada' (BSV EVO)

πŸ”„ BSV Electronic Alarma 'Falta of Sal / Célula Gastada' (BSV EVO) Reset: Descale the titanium electrode, check the salt level (5 g/l) or replace the BSV cell replacement.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for BSV Electronic Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for BSV Electronic Alarma 'Falta of Sal / Célula Gastada' (BSV EVO)?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: BSV Electronic Error Code Alarma 'Falta of Sal / Célula Gastada' (BSV EVO)

What does BSV Electronic error code Alarma 'Falta of Sal / Célula Gastada' (BSV EVO) mean?

BSV Electronic Alarma 'Falta of Sal / Célula Gastada' (BSV EVO): A Low Conductivity / Lack of Salt warning appears on the BSV chlorinator screen or it does not reach the selected grams/hour (Cloradores Salinos BSV (BS Pool, EVO Basic, EVO Auto, Smart, Touch, N-BSSalt)). Multimeter Specs: Estimated useful life of the original BSV cell: 5,000 to 10,000 hours depending on the calcium hardness of the water.

How do I reset BSV Electronic fault code Alarma 'Falta of Sal / Célula Gastada' (BSV EVO)?

Descale the titanium electrode, check the salt level (5 g/l) or replace the BSV cell replacement.

What multimeter values should I check for BSV Electronic code Alarma 'Falta of Sal / Célula Gastada' (BSV EVO)?

Estimated useful life of the original BSV cell: 5,000 to 10,000 hours depending on the calcium hardness of the water