Bosch Compress Error Code 5272 / E02: Meaning, Multimeter Diagnosis & Fix

Fault code 5272 / E02 on Bosch Compress units (Bombas of Calor Compress 3000 AW, 6000 AW, 7000i AW, Supraeco) indicates: Disparo of the limitador Thermal of the resistance Electric of apoyo (9 kW / 6 kW). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Heat Pumps (Aerothermal) subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Bosch Compress 5272 / E02)

Manufacturer / BrandBosch Compress
Error Code5272 / E02
System / CategoryHeat Pumps (Aerothermal)
Compatible ModelsBombas of Calor Compress 3000 AW, 6000 AW, 7000i AW, Supraeco
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsThermostat bimetálico of seguridad: 0 Ω closed

2. Guided Symptom Troubleshooting Matrix

🔎 Does Bosch Compress error code 5272 / E02 return immediately after a full power cycle even when main supply voltage is stable?
✓ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (Disparo of the limitador Thermal of the resistance Electric of apoyo (9 kW / 6 kW)). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: Thermostat bimetálico of seguridad: 0 Ω closed. If it reads open circuit (OL) or dead short, replace the faulty part.

✕ Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: press el Button mecánico of rearme in el cuerpo of the resistance Electric (sin voltage) and reset.

3. Step-by-Step Multimeter Testing Procedure (5272 / E02)

  1. Safety Power Isolation: Disconnect the Bosch Compress unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault 5272 / E02 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Thermostat bimetálico of seguridad: 0 Ω closed.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Bosch Compress Error 5272 / E02

🔄 Bosch Compress 5272 / E02 Reset: press el Button mecánico of rearme in el cuerpo of the resistance Electric (sin voltage) and reset.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Bosch Compress Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Bosch Compress 5272 / E02?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Bosch Compress Error Code 5272 / E02

What does Bosch Compress error code 5272 / E02 mean?

Bosch Compress 5272 / E02: Disparo of the limitador Thermal of the resistance Electric of apoyo (9 kW / 6 kW) (Bombas of Calor Compress 3000 AW, 6000 AW, 7000i AW, Supraeco). Multimeter Specs: Thermostat bimetálico of seguridad: 0 Ω closed.

How do I reset Bosch Compress fault code 5272 / E02?

press el Button mecánico of rearme in el cuerpo of the resistance Electric (sin voltage) and reset.

What multimeter values should I check for Bosch Compress code 5272 / E02?

Thermostat bimetálico of seguridad: 0 Ω closed