Ariston Nimbus Error Code Error 201 / 202 (NTC thermistor probe Depósito ACS): Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Ariston Nimbus Error 201 / 202 (NTC thermistor probe Depósito ACS))
| Manufacturer / Brand | Ariston Nimbus |
|---|---|
| Error Code | Error 201 / 202 (NTC thermistor probe Depósito ACS) |
| System / Category | Heat Pumps (Aerothermal) |
| Compatible Models | Aerotermia Ariston Nimbus (Pocket M Net, Plus M, Compact M, Flex M - Mando Sensys HD and App Ariston NET) |
| Severity Level | Medium Severity · Protection Mode |
| Multimeter Specs | NTC thermistor probe acumulador ACS Ariston Nimbus a 25°C: 10 kΩ |
2. Guided Symptom Troubleshooting Matrix
Permanent hardware or sensor circuit fault (La aerotermia Ariston Nimbus pita with 'Error 201' or '202' and no calienta el Water caliente of las duchas). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: NTC thermistor probe acumulador ACS Ariston Nimbus a 25°C: 10 kΩ. If it reads open circuit (OL) or dead short, replace the faulty part.
Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: check and test la conexión of 2 hilos of the NTC thermistor probe of the depósito of ACS in la regleta of the indoor unit or replace la Probe / Sensor (10 kΩ).
3. Step-by-Step Multimeter Testing Procedure (Error 201 / 202 (NTC thermistor probe Depósito ACS))
- Safety Power Isolation: Disconnect the Ariston Nimbus unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault Error 201 / 202 (NTC thermistor probe Depósito ACS) for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: NTC thermistor probe acumulador ACS Ariston Nimbus a 25°C: 10 kΩ.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Ariston Nimbus Error Error 201 / 202 (NTC thermistor probe Depósito ACS)
Check OEM & aftermarket availability for Ariston Nimbus NTC Temperature Sensor:
⚡ Open in Interactive Simulator →
5. Frequently Asked Questions: Ariston Nimbus Error Code Error 201 / 202 (NTC thermistor probe Depósito ACS)
What does Ariston Nimbus error code Error 201 / 202 (NTC thermistor probe Depósito ACS) mean?
Ariston Nimbus Error 201 / 202 (NTC thermistor probe Depósito ACS): La aerotermia Ariston Nimbus pita with 'Error 201' or '202' and no calienta el Water caliente of las duchas (Aerotermia Ariston Nimbus (Pocket M Net, Plus M, Compact M, Flex M - Mando Sensys HD and App Ariston NET)). Multimeter Specs: NTC thermistor probe acumulador ACS Ariston Nimbus a 25°C: 10 kΩ.
How do I reset Ariston Nimbus fault code Error 201 / 202 (NTC thermistor probe Depósito ACS)?
check and test la conexión of 2 hilos of the NTC thermistor probe of the depósito of ACS in la regleta of the indoor unit or replace la Probe / Sensor (10 kΩ).
What multimeter values should I check for Ariston Nimbus code Error 201 / 202 (NTC thermistor probe Depósito ACS)?
NTC thermistor probe acumulador ACS Ariston Nimbus a 25°C: 10 kΩ