Engineering Review: 2026-11-21 Β· SAE J2012 / IEC / OEM Verified
ESENDEFRIT
Hogar Inteligente Medium Severity · Protection Mode

Tegui Error Code Monitor Tegui / BTicino Clase 100 (2 Hilos) flashes and No Funciona: Meaning, Multimeter Diagnosis & Fix

Fault code Monitor Tegui / BTicino Clase 100 (2 Hilos) flashes and No Funciona on Tegui units (Telefonillos and Videoporteros Tegui / BTicino (Serie 7, Serie 8, M-72, Clase 100, Clase 300 WiFi - Bus 2 Hilos)) indicates: The Tegui / BTicino 2-wire video intercom does not provide image or sound after a power outage or when changing it (JMP Green Configurators). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Hogar Inteligente subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Tegui Monitor Tegui / BTicino Clase 100 (2 Hilos) flashes and No Funciona)

Manufacturer / BrandTegui
Error CodeMonitor Tegui / BTicino Clase 100 (2 Hilos) flashes and No Funciona
System / CategoryHogar Inteligente
Compatible ModelsTelefonillos and Videoporteros Tegui / BTicino (Serie 7, Serie 8, M-72, Clase 100, Clase 300 WiFi - Bus 2 Hilos)
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsThe 2-wire Tegui/BTicino systems read the resistive value of the green configurators (N) only at the moment of receiving initial voltage (27V DC)

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Have you changed your 2-wire Tegui/BTicino monitor or telephone for a new one and it is not receiving calls from your apartment?
βœ“ Scenario A: Yes (Confirmed)

Exclusive detail of all **Tegui and BTicino 2-wire devices**!: Behind the device (when you take it down from the wall) there are some **numbered holes (`N` and 'P`) where tiny green plastic pieces with a written number are inserted (they are called Physical Configurators, from 0 to 9)**. If your apartment is, for example, number 14, your old device has the green configurator **`1` and `4`** set. **If you throw the old telephone in the trash without taking out those two green chips with tweezers to press them exactly the same in the new device (with the power removed), the new device will be floor '0' and will never ring!**

βœ• Scenario B: No (Not Present)

After moving a green configurator in Tegui/BTicino, you have to **unplug the connector from the 2 white wires on the back for 30 seconds** so that it reads the numbers when you plug it back in.

3. Step-by-Step Multimeter Testing Procedure (Monitor Tegui / BTicino Clase 100 (2 Hilos) flashes and No Funciona)

  1. Safety Power Isolation: Disconnect the Tegui unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Monitor Tegui / BTicino Clase 100 (2 Hilos) flashes and No Funciona for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: The 2-wire Tegui/BTicino systems read the resistive value of the green configurators (N) only at the moment of receiving initial voltage (27V DC).
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Tegui Error Monitor Tegui / BTicino Clase 100 (2 Hilos) flashes and No Funciona

πŸ”„ Tegui Monitor Tegui / BTicino Clase 100 (2 Hilos) flashes and No Funciona Reset: Remove the numbered green configurators (boxes N) from the old device with tweezers, insert them in the same position as the new one and disconnect the bus for 30 seconds.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Tegui Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Tegui Monitor Tegui / BTicino Clase 100 (2 Hilos) flashes and No Funciona?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Tegui Error Code Monitor Tegui / BTicino Clase 100 (2 Hilos) flashes and No Funciona

What does Tegui error code Monitor Tegui / BTicino Clase 100 (2 Hilos) flashes and No Funciona mean?

Tegui Monitor Tegui / BTicino Clase 100 (2 Hilos) flashes and No Funciona: The Tegui / BTicino 2-wire video intercom does not provide image or sound after a power outage or when changing it (JMP Green Configurators) (Telefonillos and Videoporteros Tegui / BTicino (Serie 7, Serie 8, M-72, Clase 100, Clase 300 WiFi - Bus 2 Hilos)). Multimeter Specs: The 2-wire Tegui/BTicino systems read the resistive value of the green configurators (N) only at the moment of receiving initial voltage (27V DC).

How do I reset Tegui fault code Monitor Tegui / BTicino Clase 100 (2 Hilos) flashes and No Funciona?

Remove the numbered green configurators (boxes N) from the old device with tweezers, insert them in the same position as the new one and disconnect the bus for 30 seconds.

What multimeter values should I check for Tegui code Monitor Tegui / BTicino Clase 100 (2 Hilos) flashes and No Funciona?

The 2-wire Tegui/BTicino systems read the resistive value of the green configurators (N) only at the moment of receiving initial voltage (27V DC)