Pujol Error Code La Door Pujol Choca Contra el Tope Final without Parar (Final of Carrera): Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Pujol La Door Pujol Choca Contra el Tope Final without Parar (Final of Carrera))
| Manufacturer / Brand | Pujol |
|---|---|
| Error Code | La Door Pujol Choca Contra el Tope Final without Parar (Final of Carrera) |
| System / Category | Hogar Inteligente |
| Compatible Models | Motores to Puertas of Garaje Pujol Muntalá (Marathon, Mini Marathon, Winner, Júnior, Pro - Receptores Vario / EPro) |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | Pujol Marathon Limit Switches: Normally Closed Contacts (FCA = Opening, FCC = Closing) |
2. Guided Symptom Troubleshooting Matrix
At the bottom of the Pujol motor there is a **small vertical metal spring (Limit Switch mustache)** that, when touching the two plates screwed at the ends of the door rack, bends to the left or right, activating **2 internal microswitches**: 1) Check to see if the **metal plate (limit switch slide)** that is held with 2 screws on the door rack has fallen or loosened. 2) With the door halfway, move the spring to the left and right with your finger: it should sound *'click'* on each side and the `FCA` and `FCC` LEDs on the board should turn on/off; If a microswitch has broken inside, change the limit switch box (~β¬14).
Check with your finger that the limit switch spring 'clicks' on both sides and that the stop plate on the rack has not moved.
3. Step-by-Step Multimeter Testing Procedure (La Door Pujol Choca Contra el Tope Final without Parar (Final of Carrera))
- Safety Power Isolation: Disconnect the Pujol unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault La Door Pujol Choca Contra el Tope Final without Parar (Final of Carrera) for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Pujol Marathon Limit Switches: Normally Closed Contacts (FCA = Opening, FCC = Closing).
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Pujol Error La Door Pujol Choca Contra el Tope Final without Parar (Final of Carrera)
Check OEM & aftermarket availability for Pujol Replacement Sensor / Part:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Pujol Error Code La Door Pujol Choca Contra el Tope Final without Parar (Final of Carrera)
What does Pujol error code La Door Pujol Choca Contra el Tope Final without Parar (Final of Carrera) mean?
Pujol La Door Pujol Choca Contra el Tope Final without Parar (Final of Carrera): When opening or closing, the Pujol sliding door does not stop when it reaches the end, it hits against the pillar and the motor continues pushing forcefully. (Motores to Puertas of Garaje Pujol Muntalá (Marathon, Mini Marathon, Winner, Júnior, Pro - Receptores Vario / EPro)). Multimeter Specs: Pujol Marathon Limit Switches: Normally Closed Contacts (FCA = Opening, FCC = Closing).
How do I reset Pujol fault code La Door Pujol Choca Contra el Tope Final without Parar (Final of Carrera)?
Retighten the stop plates at the ends of the rack or replace the limit switch microswitch block.
What multimeter values should I check for Pujol code La Door Pujol Choca Contra el Tope Final without Parar (Final of Carrera)?
Pujol Marathon Limit Switches: Normally Closed Contacts (FCA = Opening, FCC = Closing)