Engineering Review: 2026-11-21 Β· SAE J2012 / IEC / OEM Verified
ESENDEFRIT
Pools & Lawn Mowers Low Severity · Maintenance Advisory

Sugar Valley Error Code Aviso 'FL1' in display (Flow Switch / Detector of Flujo): Meaning, Multimeter Diagnosis & Fix

Fault code Aviso 'FL1' in display (Flow Switch / Detector of Flujo) on Sugar Valley units (Equipos of Electrólisis Salina e Hidrólisis Sugar Valley (Hidrolife, Aquascenic, Oxilife, Station - Also comercializados como Hayward / Kripsol / QP)) indicates: 'FL1' appears flashing on the Sugar Valley display and both electrolysis and pH dosing are stopped. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Pools & Lawn Mowers subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Sugar Valley Aviso 'FL1' in display (Flow Switch / Detector of Flujo))

Manufacturer / BrandSugar Valley
Error CodeAviso 'FL1' in display (Flow Switch / Detector of Flujo)
System / CategoryPools & Lawn Mowers
Compatible ModelsEquipos of Electrólisis Salina e Hidrólisis Sugar Valley (Hidrolife, Aquascenic, Oxilife, Station - Also comercializados como Hayward / Kripsol / QP)
Severity LevelLow Severity · Maintenance Advisory
Multimeter SpecsFL1 contact on Sugar Valley plate: Closed dry contact with water circulation

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does the 'FL1' warning appear even though the filtration pump is on?
βœ“ Scenario A: Yes (Confirmed)

**FL1** is the input of the **Mechanical Flow Switch (paddle Flow Switch)** or the cell's free gas sensor: check that the filter selector valve is in the *Filtration* position, that there is a good jet in the pool impellers and that the flow detector cable connected to the lower strip of the plate (`FL1`) is not cut.

βœ• Scenario B: No (Not Present)

If you do not have an external vane detector installed and FL1 appears, it has been deconfigured in the installer menu (disable external Flow Switch if it only uses the cell's own gas sensor).

3. Step-by-Step Multimeter Testing Procedure (Aviso 'FL1' in display (Flow Switch / Detector of Flujo))

  1. Safety Power Isolation: Disconnect the Sugar Valley unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Aviso 'FL1' in display (Flow Switch / Detector of Flujo) for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: FL1 contact on Sugar Valley plate: Closed dry contact with water circulation.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Sugar Valley Error Aviso 'FL1' in display (Flow Switch / Detector of Flujo)

πŸ”„ Sugar Valley Aviso 'FL1' in display (Flow Switch / Detector of Flujo) Reset: Wash the sand filter to recover flow in the pipe and check the flow switch paddle (FL1).
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Sugar Valley Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Sugar Valley Aviso 'FL1' in display (Flow Switch / Detector of Flujo)?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Sugar Valley Error Code Aviso 'FL1' in display (Flow Switch / Detector of Flujo)

What does Sugar Valley error code Aviso 'FL1' in display (Flow Switch / Detector of Flujo) mean?

Sugar Valley Aviso 'FL1' in display (Flow Switch / Detector of Flujo): 'FL1' appears flashing on the Sugar Valley display and both electrolysis and pH dosing are stopped (Equipos of Electrólisis Salina e Hidrólisis Sugar Valley (Hidrolife, Aquascenic, Oxilife, Station - Also comercializados como Hayward / Kripsol / QP)). Multimeter Specs: FL1 contact on Sugar Valley plate: Closed dry contact with water circulation.

How do I reset Sugar Valley fault code Aviso 'FL1' in display (Flow Switch / Detector of Flujo)?

Wash the sand filter to recover flow in the pipe and check the flow switch paddle (FL1).

What multimeter values should I check for Sugar Valley code Aviso 'FL1' in display (Flow Switch / Detector of Flujo)?

FL1 contact on Sugar Valley plate: Closed dry contact with water circulation