Sime Error Code AL02: Meaning, Multimeter Diagnosis & Fix

Fault code AL02 on Sime units (Brava Slim, Uniqa Revolution, Metropolis, Format, Murelle) indicates: Baja pressure of Water in el primary circuit (< 0.5 bar). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Sime AL02)

Manufacturer / BrandSime
Error CodeAL02
System / CategoryBoilers & Heating
Compatible ModelsBrava Slim, Uniqa Revolution, Metropolis, Format, Murelle
Severity LevelLow Severity · Maintenance Advisory
Multimeter Specspressure trabajo in frío: 1.2 - 1.5 bar

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does Sime error code AL02 return immediately after a full power cycle even when main supply voltage is stable?
βœ“ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (Baja pressure of Water in el primary circuit (< 0.5 bar)). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: pressure trabajo in frío: 1.2 - 1.5 bar. If it reads open circuit (OL) or dead short, replace the faulty part.

βœ• Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: Rearme Automatic al superar 0.9 bar.

3. Step-by-Step Multimeter Testing Procedure (AL02)

  1. Safety Power Isolation: Disconnect the Sime unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault AL02 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: pressure trabajo in frío: 1.2 - 1.5 bar.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Sime Error AL02

πŸ”„ Sime AL02 Reset: Rearme Automatic al superar 0.9 bar.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Sime Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Sime AL02?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Sime Error Code AL02

What does Sime error code AL02 mean?

Sime AL02: Baja pressure of Water in el primary circuit (< 0.5 bar) (Brava Slim, Uniqa Revolution, Metropolis, Format, Murelle). Multimeter Specs: pressure trabajo in frío: 1.2 - 1.5 bar.

How do I reset Sime fault code AL02?

Rearme Automatic al superar 0.9 bar.

What multimeter values should I check for Sime code AL02?

pressure trabajo in frío: 1.2 - 1.5 bar