Rain Bird Error Code Un Sector of Aspersores No Se Apaga Nunca Aunque Desenchufes el Programador: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Rain Bird Un Sector of Aspersores No Se Apaga Nunca Aunque Desenchufes el Programador)
| Manufacturer / Brand | Rain Bird |
|---|---|
| Error Code | Un Sector of Aspersores No Se Apaga Nunca Aunque Desenchufes el Programador |
| System / Category | Pools & Lawn Mowers |
| Compatible Models | Programadores of Riego Automatic and Electroválvulas Rain Bird (ESP-RZXe, ESP-Me, ESP-TM2, WPX / TBOS a Pilas, Válvulas 100-DV / PGA) |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | The irrigation solenoid valves close by hydraulic pressure in the upper chamber of the membrane; any grain of sand on the seat prevents physical closure |
2. Guided Symptom Troubleshooting Matrix
Definitive test!: **If water continues to come out with the programmer unplugged from the light, the problem is NOT electrical or with the programmer**: inside the **Electronic valve buried in the green manhole in the garden (Rain Bird `100-DV` or `HV` model)** a **pebble, grit or piece of Teflon** has gotten into the little hole in the **Rubber Membrane (Diaphragm)**, preventing the water pressure from lowering the rubber plug to close. **How to fix it yourself in 5 minutes in the garden**: 1) Close the main irrigation water tap. 2) Go to the green box, first check that the **Black solenoid and the bleed screw** are closed tightly to the right ('OFF'). 3) Remove the **6 star screws from the top cover of that solenoid valve**, remove the round black rubber (membrane) and the spring, **wash it with clean water removing the small stone** (or put a replacement Rain Bird 100-DV membrane for ~β¬9) and screw the cover back on.
Never use pliers to tighten the black plastic solenoid; It is screwed only with finger strength until its O-ring stops.
3. Step-by-Step Multimeter Testing Procedure (Un Sector of Aspersores No Se Apaga Nunca Aunque Desenchufes el Programador)
- Safety Power Isolation: Disconnect the Rain Bird unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault Un Sector of Aspersores No Se Apaga Nunca Aunque Desenchufes el Programador for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: The irrigation solenoid valves close by hydraulic pressure in the upper chamber of the membrane; any grain of sand on the seat prevents physical closure.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Rain Bird Error Un Sector of Aspersores No Se Apaga Nunca Aunque Desenchufes el Programador
Check OEM & aftermarket availability for Rain Bird Replacement Sensor / Part:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Rain Bird Error Code Un Sector of Aspersores No Se Apaga Nunca Aunque Desenchufes el Programador
What does Rain Bird error code Un Sector of Aspersores No Se Apaga Nunca Aunque Desenchufes el Programador mean?
Rain Bird Un Sector of Aspersores No Se Apaga Nunca Aunque Desenchufes el Programador: The watering time ends (and you even unplug the Rain Bird controller from the wall) but an area of the garden continues to water non-stop (Programadores of Riego Automatic and Electroválvulas Rain Bird (ESP-RZXe, ESP-Me, ESP-TM2, WPX / TBOS a Pilas, Válvulas 100-DV / PGA)). Multimeter Specs: The irrigation solenoid valves close by hydraulic pressure in the upper chamber of the membrane; any grain of sand on the seat prevents physical closure.
How do I reset Rain Bird fault code Un Sector of Aspersores No Se Apaga Nunca Aunque Desenchufes el Programador?
Close the main valve, remove the 6 upper screws of the solenoid valve in the manhole and clean the sand trapped under the rubber membrane (diaphragm).
What multimeter values should I check for Rain Bird code Un Sector of Aspersores No Se Apaga Nunca Aunque Desenchufes el Programador?
The irrigation solenoid valves close by hydraulic pressure in the upper chamber of the membrane; any grain of sand on the seat prevents physical closure