Engineering Review: 2026-11-21 Β· SAE J2012 / IEC / OEM Verified
ESENDEFRIT
Hogar Inteligente High Severity · Safety Lockout

Hörmann Error Code Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic): Meaning, Multimeter Diagnosis & Fix

Fault code Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic) on Hörmann units (Motores Alemanes to Puertas Seccionales and Garaje Hörmann (ProMatic Serie 2/3/4, SupraMatic E/P, RollMatic, RotaMatic, LineaMatic)) indicates: The Hörmann SupraMatic roof motor shows the number '3', '4' or '5' flashing (or the red LED on the ProMatic flashes 3 or 5 times) and the door bounces when lowered. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Hogar Inteligente subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Hörmann Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic))

Manufacturer / BrandHörmann
Error CodeError 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic)
System / CategoryHogar Inteligente
Compatible ModelsMotores Alemanes to Puertas Seccionales and Garaje Hörmann (ProMatic Serie 2/3/4, SupraMatic E/P, RollMatic, RotaMatic, LineaMatic)
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsHörmann ProMatic red LED flash table: 2=Photocell | 3=Stop circuit open | 5=Excess force/obstacle | 6=Internal system failure

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does your Hörmann sectional door try to close, stop halfway and go up again showing a 3 or 5 on the roof motor?
βœ“ Scenario A: Yes (Confirmed)

Official diagnostic table **Hörmann SupraMatic (7-segment display) and ProMatic (red LED flashes)**: β€’ **Code `5` (or 5 red flashes)**: **Force limitation activated**. The door rubs on the guides or an upper spring has loosened/broken. Unhook the cart by pulling the green/red knob, check that the door goes up and down smoothly with just one hand and perform a **Route Learning Menu (`L` / Menu `1`)**. β€’ **Code `3` (or 3 flashes)**: The emergency stop circuit or the **microswitch of the pedestrian door inserted / cable release** is open. β€’ **Code `4` (or 2 flashes)**: **The safety photocell (`EL 101 / EL 301`) is dirty or misaligned**. β€’ **Code `8`**: It is not a fault; It means that it requests a maintenance inspection (it is removed by doing a complete cycle or restarting).

βœ• Scenario B: No (Not Present)

If a **`L`** flashes on the Hörmann display after a power outage: the motor asks to do the learning run; Press the **Up `β–²`** button, the door will make 2 or 3 complete ups and downs by itself to memorize the stops and the force, do not stop it until the `L` goes out!

3. Step-by-Step Multimeter Testing Procedure (Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic))

  1. Safety Power Isolation: Disconnect the Hörmann unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic) for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Hörmann ProMatic red LED flash table: 2=Photocell | 3=Stop circuit open | 5=Excess force/obstacle | 6=Internal system failure.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Hörmann Error Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic)

πŸ”„ Hörmann Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic) Reset: Clean photocells (Code 4) or perform a new cycle of learning forces and end positions (Code 5 / Letter L).
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Hörmann Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Hörmann Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic)?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Hörmann Error Code Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic)

What does Hörmann error code Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic) mean?

Hörmann Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic): The Hörmann SupraMatic roof motor shows the number '3', '4' or '5' flashing (or the red LED on the ProMatic flashes 3 or 5 times) and the door bounces when lowered (Motores Alemanes to Puertas Seccionales and Garaje Hörmann (ProMatic Serie 2/3/4, SupraMatic E/P, RollMatic, RotaMatic, LineaMatic)). Multimeter Specs: Hörmann ProMatic red LED flash table: 2=Photocell | 3=Stop circuit open | 5=Excess force/obstacle | 6=Internal system failure.

How do I reset Hörmann fault code Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic)?

Clean photocells (Code 4) or perform a new cycle of learning forces and end positions (Code 5 / Letter L).

What multimeter values should I check for Hörmann code Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic)?

Hörmann ProMatic red LED flash table: 2=Photocell | 3=Stop circuit open | 5=Excess force/obstacle | 6=Internal system failure