Hörmann Error Code Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic): Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Hörmann Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic))
| Manufacturer / Brand | Hörmann |
|---|---|
| Error Code | Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic) |
| System / Category | Hogar Inteligente |
| Compatible Models | Motores Alemanes to Puertas Seccionales and Garaje Hörmann (ProMatic Serie 2/3/4, SupraMatic E/P, RollMatic, RotaMatic, LineaMatic) |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | Hörmann ProMatic red LED flash table: 2=Photocell | 3=Stop circuit open | 5=Excess force/obstacle | 6=Internal system failure |
2. Guided Symptom Troubleshooting Matrix
Official diagnostic table **Hörmann SupraMatic (7-segment display) and ProMatic (red LED flashes)**: β’ **Code `5` (or 5 red flashes)**: **Force limitation activated**. The door rubs on the guides or an upper spring has loosened/broken. Unhook the cart by pulling the green/red knob, check that the door goes up and down smoothly with just one hand and perform a **Route Learning Menu (`L` / Menu `1`)**. β’ **Code `3` (or 3 flashes)**: The emergency stop circuit or the **microswitch of the pedestrian door inserted / cable release** is open. β’ **Code `4` (or 2 flashes)**: **The safety photocell (`EL 101 / EL 301`) is dirty or misaligned**. β’ **Code `8`**: It is not a fault; It means that it requests a maintenance inspection (it is removed by doing a complete cycle or restarting).
If a **`L`** flashes on the Hörmann display after a power outage: the motor asks to do the learning run; Press the **Up `β²`** button, the door will make 2 or 3 complete ups and downs by itself to memorize the stops and the force, do not stop it until the `L` goes out!
3. Step-by-Step Multimeter Testing Procedure (Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic))
- Safety Power Isolation: Disconnect the Hörmann unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic) for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Hörmann ProMatic red LED flash table: 2=Photocell | 3=Stop circuit open | 5=Excess force/obstacle | 6=Internal system failure.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Hörmann Error Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic)
Check OEM & aftermarket availability for Hörmann Replacement Sensor / Part:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Hörmann Error Code Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic)
What does Hörmann error code Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic) mean?
Hörmann Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic): The Hörmann SupraMatic roof motor shows the number '3', '4' or '5' flashing (or the red LED on the ProMatic flashes 3 or 5 times) and the door bounces when lowered (Motores Alemanes to Puertas Seccionales and Garaje Hörmann (ProMatic Serie 2/3/4, SupraMatic E/P, RollMatic, RotaMatic, LineaMatic)). Multimeter Specs: Hörmann ProMatic red LED flash table: 2=Photocell | 3=Stop circuit open | 5=Excess force/obstacle | 6=Internal system failure.
How do I reset Hörmann fault code Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic)?
Clean photocells (Code 4) or perform a new cycle of learning forces and end positions (Code 5 / Letter L).
What multimeter values should I check for Hörmann code Error 3 / Error 4 / Error 5 in display SupraMatic (o 3/5 Parpadeos in ProMatic)?
Hörmann ProMatic red LED flash table: 2=Photocell | 3=Stop circuit open | 5=Excess force/obstacle | 6=Internal system failure