1. Technical Specifications & Multimeter Values (Ósmosis Inversa (Bbagua / ATH / Philips) Pump No to Nunca / Desagua Continuo)
| Manufacturer / Brand | Ósmosis Inversa (Bbagua / ATH / Philips) |
|---|---|
| Error Code | Pump No to Nunca / Desagua Continuo |
| System / Category | Pools & Lawn Mowers |
| Compatible Models | Equipos of Ósmosis Inversa of 5 Etapas with Pump and Flujo Directo (Bbagua, ATH Genius, Ionfilter, Puragua, Philips AUT) |
| Severity Level | Medium Severity · Protection Mode |
| Multimeter Specs | Osmosis tank air pressure (completely empty of water): 0.4 to 0.5 bar (6-7 PSI) |
2. Guided Symptom Troubleshooting Matrix
In a reverse osmosis unit there are two pieces that cut off the flow when the tank is already full: 1) If it has an electric pump: the **High Pressure Switch (black piece with 2 Faston cables)** has a tired membrane or does not reach 2.5 bar because the osmosis membrane is clogged (you can adjust it by turning the small **central Allen screw** that has the high pressure switch a quarter of a turn counterclockwise. at one end). 2) If it does NOT have an electrical plug (osmosis without pump): the **4-Way Valve (Shut-Off Valve, white/black piece where 4 tubes fit)** has the internal diaphragm perforated by lime (change it for β¬8).
Also check the air pressure in the accumulator tank (in vacuum without water it should be **0.5 bar / 7 PSI** at the lower tire valve).
3. Step-by-Step Multimeter Testing Procedure (Pump No to Nunca / Desagua Continuo)
- Safety Power Isolation: Disconnect the Ósmosis Inversa (Bbagua / ATH / Philips) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault Pump No to Nunca / Desagua Continuo for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Osmosis tank air pressure (completely empty of water): 0.4 to 0.5 bar (6-7 PSI).
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Ósmosis Inversa (Bbagua / ATH / Philips) Error Pump No to Nunca / Desagua Continuo
Check OEM & aftermarket availability for Ósmosis Inversa Drain Pump:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Ósmosis Inversa (Bbagua / ATH / Philips) Error Code Pump No to Nunca / Desagua Continuo
What does Ósmosis Inversa (Bbagua / ATH / Philips) error code Pump No to Nunca / Desagua Continuo mean?
Ósmosis Inversa (Bbagua / ATH / Philips) Pump No to Nunca / Desagua Continuo: The osmosis pump motor under the sink never turns off or throws water down the drain 24 hours a day non-stop (Equipos of Ósmosis Inversa of 5 Etapas with Pump and Flujo Directo (Bbagua, ATH Genius, Ionfilter, Puragua, Philips AUT)). Multimeter Specs: Osmosis tank air pressure (completely empty of water): 0.4 to 0.5 bar (6-7 PSI).
How do I reset Ósmosis Inversa (Bbagua / ATH / Philips) fault code Pump No to Nunca / Desagua Continuo?
Replace the automatic 4-way shut-off valve (Shut-Off) or adjust the Allen screw of the high pressure switch half a turn.
What multimeter values should I check for Ósmosis Inversa (Bbagua / ATH / Philips) code Pump No to Nunca / Desagua Continuo?
Osmosis tank air pressure (completely empty of water): 0.4 to 0.5 bar (6-7 PSI)