Ökofen / Fröling / Hargassner (Biomasa) Error Code Fault / Failure ignition / without Flame (Biomasa): Meaning, Multimeter Diagnosis & Fix

Fault code Fault / Failure ignition / without Flame (Biomasa) on Ökofen / Fröling / Hargassner (Biomasa) units (Boilers of Pellets and Astilla Ökofen Pellematic (Compact, Condens), Fröling P4/S4/PE1, Hargassner Nano-PK, Lasian Bio) indicates: Ignition time exceeded: No rise in smoke temperature or flame light in the burner is detected. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Ökofen / Fröling / Hargassner (Biomasa) Fault / Failure ignition / without Flame (Biomasa))

Manufacturer / BrandÖkofen / Fröling / Hargassner (Biomasa)
Error CodeFault / Failure ignition / without Flame (Biomasa)
System / CategoryBoilers & Heating
Compatible ModelsBoilers of Pellets and Astilla Ökofen Pellematic (Compact, Condens), Fröling P4/S4/PE1, Hargassner Nano-PK, Lasian Bio
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsCeramic ignition cartridge resistance 230V (300W): ~175 Ω | Ignition blower (1000W): ~52 Ω

2. Guided Symptom Troubleshooting Matrix

🔎 Does the combustion dish or brazier have unburned raw pellets after blocking or is it completely empty?
✓ Scenario A: Yes (Confirmed)

1) **If the plate is full of cold raw pellets**: the **ceramic resistance/ignition blower (250W-1000W)** has melted or the slag (clinker) covers the nozzle through which the incandescent air blows. 2) **If the plate is completely empty of pellets**: the pneumatic suction system or the silo auger has become clogged (or the Bélimo fire stop valve has not opened completely).

✕ Scenario B: No (Not Present)

Always remove unburned pellets from the plate before resetting the boiler to avoid a dense smoke explosion in the boiler room.

3. Step-by-Step Multimeter Testing Procedure (Fault / Failure ignition / without Flame (Biomasa))

  1. Safety Power Isolation: Disconnect the Ökofen / Fröling / Hargassner (Biomasa) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Fault / Failure ignition / without Flame (Biomasa) for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Ceramic ignition cartridge resistance 230V (300W): ~175 Ω | Ignition blower (1000W): ~52 Ω.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Ökofen / Fröling / Hargassner (Biomasa) Error Fault / Failure ignition / without Flame (Biomasa)

🔄 Ökofen / Fröling / Hargassner (Biomasa) Fault / Failure ignition / without Flame (Biomasa) Reset: Empty the raw pellets from the burner plate, clean the spark plug groove and press alarm confirmation on the touch screen.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (Ignition & Flame Electrode)?

Check OEM & aftermarket availability for Ökofen Ignition & Flame Electrode:

Want to use the interactive diagnostic wizard or electrical calculators for Ökofen / Fröling / Hargassner (Biomasa) Fault / Failure ignition / without Flame (Biomasa)?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Ökofen / Fröling / Hargassner (Biomasa) Error Code Fault / Failure ignition / without Flame (Biomasa)

What does Ökofen / Fröling / Hargassner (Biomasa) error code Fault / Failure ignition / without Flame (Biomasa) mean?

Ökofen / Fröling / Hargassner (Biomasa) Fault / Failure ignition / without Flame (Biomasa): Ignition time exceeded: No rise in smoke temperature or flame light in the burner is detected (Boilers of Pellets and Astilla Ökofen Pellematic (Compact, Condens), Fröling P4/S4/PE1, Hargassner Nano-PK, Lasian Bio). Multimeter Specs: Ceramic ignition cartridge resistance 230V (300W): ~175 Ω | Ignition blower (1000W): ~52 Ω.

How do I reset Ökofen / Fröling / Hargassner (Biomasa) fault code Fault / Failure ignition / without Flame (Biomasa)?

Empty the raw pellets from the burner plate, clean the spark plug groove and press alarm confirmation on the touch screen.

What multimeter values should I check for Ökofen / Fröling / Hargassner (Biomasa) code Fault / Failure ignition / without Flame (Biomasa)?

Ceramic ignition cartridge resistance 230V (300W): ~175 Ω | Ignition blower (1000W): ~52 Ω