Liebherr Error Code F2: Meaning, Multimeter Diagnosis & Fix

Fault code F2 on Liebherr units (Comfort, Premium, BioFresh, NoFrost, CN, CBN, KGN) indicates: Fault / Failure in la NTC thermistor probe of the Evaporator of the refrigerador (La pared trasera hace una Board / Plate gruesa of hielo or congela las verduras). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Refrigerators & Freezers subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Liebherr F2)

Manufacturer / BrandLiebherr
Error CodeF2
System / CategoryRefrigerators & Freezers
Compatible ModelsComfort, Premium, BioFresh, NoFrost, CN, CBN, KGN
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsNTC sensors Liebherr a 25°C: 4.7 kΩ (a +5°C: ~11.9 kΩ | a -18°C: ~40 kΩ)

2. Guided Symptom Troubleshooting Matrix

🔎 Does Liebherr error code F2 return immediately after a full power cycle even when main supply voltage is stable?
✓ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (Fault / Failure in la NTC thermistor probe of the Evaporator of the refrigerador (La pared trasera hace una Board / Plate gruesa of hielo or congela las verduras)). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: NTC sensors Liebherr a 25°C: 4.7 kΩ (a +5°C: ~11.9 kΩ | a -18°C: ~40 kΩ). If it reads open circuit (OL) or dead short, replace the faulty part.

✕ Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: replace la Probe / Sensor of the Evaporator interior (cable with marca verde) due to el kit of reparación Liebherr of 4.7 kΩ.

3. Step-by-Step Multimeter Testing Procedure (F2)

  1. Safety Power Isolation: Disconnect the Liebherr unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault F2 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: NTC sensors Liebherr a 25°C: 4.7 kΩ (a +5°C: ~11.9 kΩ | a -18°C: ~40 kΩ).
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Liebherr Error F2

🔄 Liebherr F2 Reset: replace la Probe / Sensor of the Evaporator interior (cable with marca verde) due to el kit of reparación Liebherr of 4.7 kΩ.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for Liebherr NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for Liebherr F2?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Liebherr Error Code F2

What does Liebherr error code F2 mean?

Liebherr F2: Fault / Failure in la NTC thermistor probe of the Evaporator of the refrigerador (La pared trasera hace una Board / Plate gruesa of hielo or congela las verduras) (Comfort, Premium, BioFresh, NoFrost, CN, CBN, KGN). Multimeter Specs: NTC sensors Liebherr a 25°C: 4.7 kΩ (a +5°C: ~11.9 kΩ | a -18°C: ~40 kΩ).

How do I reset Liebherr fault code F2?

replace la Probe / Sensor of the Evaporator interior (cable with marca verde) due to el kit of reparación Liebherr of 4.7 kΩ.

What multimeter values should I check for Liebherr code F2?

NTC sensors Liebherr a 25°C: 4.7 kΩ (a +5°C: ~11.9 kΩ | a -18°C: ~40 kΩ)