Induction Teka / Electrolux / AEG Error Code E4 / E5 / E6 / E9: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Induction Teka / Electrolux / AEG E4 / E5 / E6 / E9)
| Manufacturer / Brand | Induction Teka / Electrolux / AEG |
|---|---|
| Error Code | E4 / E5 / E6 / E9 |
| System / Category | Dryers & Ovens |
| Compatible Models | Placas of Induction and Vitrocerámicas Teka (IR, IBC, IZF), Electrolux, AEG and Zanussi |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | NTC probe center of inductor coil at 25°C: 100 kΩ |
2. Guided Symptom Troubleshooting Matrix
1) **On Teka (`E4` or `E5`)**: the NTC temperature probe located in the center of the induction plate (under the glass with white thermal paste) has opened or the lower fan that blows air under the cabinet is blocked by a cutlery drawer that is too close together without a ventilation grille. 2) **On AEG / Electrolux (`E9` or `E6`)**: touch interface board configuration failure or voltage drop; cut off the kitchen automatic on the light box for **5 minutes**.
Always leave a **front gap of 5mm to 10mm between the hob and the oven/drawer** so that the bottom fan of the induction can expel hot air.
3. Step-by-Step Multimeter Testing Procedure (E4 / E5 / E6 / E9)
- Safety Power Isolation: Disconnect the Induction Teka / Electrolux / AEG unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault E4 / E5 / E6 / E9 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: NTC probe center of inductor coil at 25°C: 100 kΩ.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Induction Teka / Electrolux / AEG Error E4 / E5 / E6 / E9
Check OEM & aftermarket availability for Induction Teka NTC Temperature Sensor:
⚡ Open in Interactive Simulator →
5. Frequently Asked Questions: Induction Teka / Electrolux / AEG Error Code E4 / E5 / E6 / E9
What does Induction Teka / Electrolux / AEG error code E4 / E5 / E6 / E9 mean?
Induction Teka / Electrolux / AEG E4 / E5 / E6 / E9: Communication error or failure in the power module / NTC probe of the inductor (Codes E4, E5, E6 or E9) (Placas of Induction and Vitrocerámicas Teka (IR, IBC, IZF), Electrolux, AEG and Zanussi). Multimeter Specs: NTC probe center of inductor coil at 25°C: 100 kΩ.
How do I reset Induction Teka / Electrolux / AEG fault code E4 / E5 / E6 / E9?
Cut off the 25A circuit breaker from the electrical panel for 5 minutes and ensure that the lower fan grill of the plate is not covered by the drawer.
What multimeter values should I check for Induction Teka / Electrolux / AEG code E4 / E5 / E6 / E9?
NTC probe center of inductor coil at 25°C: 100 kΩ