Teka Error Code Er01: Meaning, Multimeter Diagnosis & Fix
Fault code Er01 on Teka units (Hornos HBB, HLB, HSB, HydroClean and Pirolíticos) indicates: Oven temperature probe (Thermocouple PT500 / PT1000) open or shorted. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Dryers & Ovens subsystem falls outside factory tolerances.
1. Technical Specifications & Multimeter Values (Teka Er01)
| Manufacturer / Brand | Teka |
|---|---|
| Error Code | Er01 |
| System / Category | Dryers & Ovens |
| Compatible Models | Hornos HBB, HLB, HSB, HydroClean and Pirolíticos |
| Severity Level | Medium Severity · Protection Mode |
| Multimeter Specs | PT500 probe at 20°C: ~538 Ω | PT1000 probe at 20°C: ~1077 Ω |
2. Guided Symptom Troubleshooting Matrix
🔎 Does the oven beep with Er01 (or E01) and turn off the heating elements?
✓ Scenario A: Yes (Confirmed)
The thin metal probe that appears at the top of the interior of the oven has a loose connector at the back or is cut internally.
✕ Scenario B: No (Not Present)
Take the oven out of the cabinet (cutting off the light first) and measure the resistance of the rear probe.
3. Step-by-Step Multimeter Testing Procedure (Er01)
- Safety Power Isolation: Disconnect the Teka unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault Er01 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: PT500 probe at 20°C: ~538 Ω | PT1000 probe at 20°C: ~1077 Ω.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Teka Error Er01
🔄 Teka Er01 Reset: Replace the rear PT500/PT1000 thermal probe and restart power.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?
Check OEM & aftermarket availability for Teka Replacement Sensor / Part:
Want to use the interactive diagnostic wizard or electrical calculators for Teka Er01?
⚡ Open in Interactive Simulator →
⚡ Open in Interactive Simulator →
5. Frequently Asked Questions: Teka Error Code Er01
What does Teka error code Er01 mean?
Teka Er01: Oven temperature probe (Thermocouple PT500 / PT1000) open or shorted (Hornos HBB, HLB, HSB, HydroClean and Pirolíticos). Multimeter Specs: PT500 probe at 20°C: ~538 Ω | PT1000 probe at 20°C: ~1077 Ω.
How do I reset Teka fault code Er01?
Replace the rear PT500/PT1000 thermal probe and restart power.
What multimeter values should I check for Teka code Er01?
PT500 probe at 20°C: ~538 Ω | PT1000 probe at 20°C: ~1077 Ω