Hunter Error Code display Hunter Muestra 'NO AC' or 'ERR' in Estación: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Hunter display Hunter Muestra 'NO AC' or 'ERR' in Estación)
| Manufacturer / Brand | Hunter |
|---|---|
| Error Code | display Hunter Muestra 'NO AC' or 'ERR' in Estación |
| System / Category | Pools & Lawn Mowers |
| Compatible Models | Programadores of Riego and Aspersores Hunter (X-Core, Pro-C, Eco-Logic, Hydrawise HC, NODE a Pilas - Electroválvulas PGV and Aspersores PGP) |
| Severity Level | Medium Severity · Protection Mode |
| Multimeter Specs | Hunter 24V AC solenoid resistance (red wires): ~24 Ω to 45 Ω |On Hunter NODE battery-powered programmers: use Latch DC solenoids (black and red wires ~4 Ω - 9 Ω) |
2. Guided Symptom Troubleshooting Matrix
1) **For `NO AC`**: the screen remains on thanks to the internal `CR2032` button battery (which keeps the time), but **24V AC current is not reaching it from the socket**. Check if the garage differential has tripped or measure with the multimeter in AC (`V~`) on the first two **`24VAC`** screws of the Hunter's power strip: if there is no **24V - 26V AC**, the small **external wall transformer** has burned out. 2) **For `ERR` with a number in front (e.g. `2 ERR`)**: short circuit in the solenoid or in the cable of valve no. 2 in the manhole. **Total Reset Trick in Hunter
Replace the CR2032 button battery in the cable compartment every 2 years so that you do not lose the programming during power outages.
3. Step-by-Step Multimeter Testing Procedure (display Hunter Muestra 'NO AC' or 'ERR' in Estación)
- Safety Power Isolation: Disconnect the Hunter unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault display Hunter Muestra 'NO AC' or 'ERR' in Estación for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Hunter 24V AC solenoid resistance (red wires): ~24 Ω to 45 Ω |On Hunter NODE battery-powered programmers: use Latch DC solenoids (black and red wires ~4 Ω - 9 Ω).
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Hunter Error display Hunter Muestra 'NO AC' or 'ERR' in Estación
Check OEM & aftermarket availability for Hunter Replacement Sensor / Part:
⚡ Open in Interactive Simulator →
5. Frequently Asked Questions: Hunter Error Code display Hunter Muestra 'NO AC' or 'ERR' in Estación
What does Hunter error code display Hunter Muestra 'NO AC' or 'ERR' in Estación mean?
Hunter display Hunter Muestra 'NO AC' or 'ERR' in Estación: 'NO AC' or 'ERR' appears on the Hunter X-Core or Pro-C irrigation controller display when activating a zone (Programadores of Riego and Aspersores Hunter (X-Core, Pro-C, Eco-Logic, Hydrawise HC, NODE a Pilas - Electroválvulas PGV and Aspersores PGP)). Multimeter Specs: Hunter 24V AC solenoid resistance (red wires): ~24 Ω to 45 Ω |On Hunter NODE battery-powered programmers: use Latch DC solenoids (black and red wires ~4 Ω - 9 Ω).
How do I reset Hunter fault code display Hunter Muestra 'NO AC' or 'ERR' in Estación?
For 'NO AC': check the plug and the 24V AC output of the transformer. For 'ERR': check the solenoid of the PGV solenoid valve of that sector.
What multimeter values should I check for Hunter code display Hunter Muestra 'NO AC' or 'ERR' in Estación?
Hunter 24V AC solenoid resistance (red wires): ~24 Ω to 45 Ω |On Hunter NODE battery-powered programmers: use Latch DC solenoids (black and red wires ~4 Ω - 9 Ω)