Hitachi Error Code 3 Parpadeos (Comp): Meaning, Multimeter Diagnosis & Fix

Fault code 3 Parpadeos (Comp) on Hitachi units (Mokai, Dodai, AirHome 400/600, Shirokuma, Ducted RAD/RPI, Yutaki) indicates: Sobrecorriente or falta of sincronismo in el startup of the DC inverter compressor (3 parpadeos LED exterior / Code 02-03). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Air Conditioning subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Hitachi 3 Parpadeos (Comp))

Manufacturer / BrandHitachi
Error Code3 Parpadeos (Comp)
System / CategoryAir Conditioning
Compatible ModelsMokai, Dodai, AirHome 400/600, Shirokuma, Ducted RAD/RPI, Yutaki
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsBobinados Compressor Hitachi: ~1.1 Ω - 2.0 Ω between fases

2. Guided Symptom Troubleshooting Matrix

🔎 Does Hitachi error code 3 Parpadeos (Comp) return immediately after a full power cycle even when main supply voltage is stable?
✓ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (Sobrecorriente or falta of sincronismo in el startup of the DC inverter compressor (3 parpadeos LED exterior / Code 02-03)). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: Bobinados Compressor Hitachi: ~1.1 Ω - 2.0 Ω between fases. If it reads open circuit (OL) or dead short, replace the faulty part.

✕ Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: Turn off the main circuit breaker for For / During 5 minutes.

3. Step-by-Step Multimeter Testing Procedure (3 Parpadeos (Comp))

  1. Safety Power Isolation: Disconnect the Hitachi unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault 3 Parpadeos (Comp) for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Bobinados Compressor Hitachi: ~1.1 Ω - 2.0 Ω between fases.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Hitachi Error 3 Parpadeos (Comp)

🔄 Hitachi 3 Parpadeos (Comp) Reset: Turn off the main circuit breaker for For / During 5 minutes.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Hitachi Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Hitachi 3 Parpadeos (Comp)?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Hitachi Error Code 3 Parpadeos (Comp)

What does Hitachi error code 3 Parpadeos (Comp) mean?

Hitachi 3 Parpadeos (Comp): Sobrecorriente or falta of sincronismo in el startup of the DC inverter compressor (3 parpadeos LED exterior / Code 02-03) (Mokai, Dodai, AirHome 400/600, Shirokuma, Ducted RAD/RPI, Yutaki). Multimeter Specs: Bobinados Compressor Hitachi: ~1.1 Ω - 2.0 Ω between fases.

How do I reset Hitachi fault code 3 Parpadeos (Comp)?

Turn off the main circuit breaker for For / During 5 minutes.

What multimeter values should I check for Hitachi code 3 Parpadeos (Comp)?

Bobinados Compressor Hitachi: ~1.1 Ω - 2.0 Ω between fases