Hisense (Refrigerators) Error Code E1 / E2 / E3 / E4: Meaning, Multimeter Diagnosis & Fix

Fault code E1 / E2 / E3 / E4 on Hisense (Refrigerators) units (Refrigerators Combi, Americanos Side by Side and Cross Door Hisense (RB390, RB440, RS677, RQ563, RQ758)) indicates: Failure in the NTC temperature probes: Refrigerator (E1), Freezer (E2), 0°C Zone (E3) or Evaporator defrost probe (E4). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Refrigerators & Freezers subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Hisense (Refrigerators) E1 / E2 / E3 / E4)

Manufacturer / BrandHisense (Refrigerators)
Error CodeE1 / E2 / E3 / E4
System / CategoryRefrigerators & Freezers
Compatible ModelsRefrigerators Combi, Americanos Side by Side and Cross Door Hisense (RB390, RB440, RS677, RQ563, RQ758)
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsHisense NTC probe at 25°C: ~2.0 kΩ (or 5 kΩ depending on model; at 0°C it rises to ~5.5 kΩ - 15 kΩ)

2. Guided Symptom Troubleshooting Matrix

🔎 Is your Hisense refrigerator screen beeping showing E1, E2, E3 or E4?
✓ Scenario A: Yes (Confirmed)

The top plate does not read the value in Ohms of that NTC probe: 1) First **unplug the refrigerator from the wall for 10 minutes** (sometimes after a storm the microprocessor freezes with E1/E4). 2) If it is **E4 (freezer evaporator probe)**: it is usually encapsulated in a small white bag attached with a zip tie to the aluminum tube of the evaporator behind the bottom cover of the freezer (it costs ~€9 and is changed with two waterproof connections).

✕ Scenario B: No (Not Present)

Also check the connector that goes through the upper right/left hinge of the refrigerator roof.

3. Step-by-Step Multimeter Testing Procedure (E1 / E2 / E3 / E4)

  1. Safety Power Isolation: Disconnect the Hisense (Refrigerators) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault E1 / E2 / E3 / E4 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Hisense NTC probe at 25°C: ~2.0 kΩ (or 5 kΩ depending on model; at 0°C it rises to ~5.5 kΩ - 15 kΩ).
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Hisense (Refrigerators) Error E1 / E2 / E3 / E4

🔄 Hisense (Refrigerators) E1 / E2 / E3 / E4 Reset: Unplug 10 minutes; If the code persists, replace the corresponding NTC probe (especially the defrost probe in E4).
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for Hisense NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for Hisense (Refrigerators) E1 / E2 / E3 / E4?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Hisense (Refrigerators) Error Code E1 / E2 / E3 / E4

What does Hisense (Refrigerators) error code E1 / E2 / E3 / E4 mean?

Hisense (Refrigerators) E1 / E2 / E3 / E4: Failure in the NTC temperature probes: Refrigerator (E1), Freezer (E2), 0°C Zone (E3) or Evaporator defrost probe (E4) (Refrigerators Combi, Americanos Side by Side and Cross Door Hisense (RB390, RB440, RS677, RQ563, RQ758)). Multimeter Specs: Hisense NTC probe at 25°C: ~2.0 kΩ (or 5 kΩ depending on model; at 0°C it rises to ~5.5 kΩ - 15 kΩ).

How do I reset Hisense (Refrigerators) fault code E1 / E2 / E3 / E4?

Unplug 10 minutes; If the code persists, replace the corresponding NTC probe (especially the defrost probe in E4).

What multimeter values should I check for Hisense (Refrigerators) code E1 / E2 / E3 / E4?

Hisense NTC probe at 25°C: ~2.0 kΩ (or 5 kΩ depending on model; at 0°C it rises to ~5.5 kΩ - 15 kΩ)